Pilz PMC Series Installation Manual page 117

Motion control
Table of Contents

Advertisement

12 Appendix
K
L
M
N
O
P
R
S
T
Z
Installation manual for PMC tendo DD5/PMCprimo Drive3
Kp, P-gain
Limit speed (final speed)
Limit switch
Machine
Motion block
Multi-axis system
Natural convection
Optocoupler
P-controller
Phase shift
PI-controller
Position controller
Potential isolation
Power contactor
Pulse power of the regen circuit
regen circuit
Reset
Resolver/digital converter
Reversing mode
Ring core
ROD-interface
Servo amplifier
Setpoint ramps
Short-circuit
Speed controller
SSI-interface
Supply filter
Tachometer voltage
Thermostat (contact)
Tn, I-integration time
Zero pulse
Proportional gain of a control loop
Maximum value for speed normalization at ±10V
Switch limiting the traverse path of the machine;
implemented as n.c. (break) contact
The complete assembly of all connected parts or
devices, of which at least one is movable
Data packet with all the position control
parameters which are required for a motion task
Machine with several independently driven axes
Free movement of air for cooling
Optical connection between two electrically
independent systems
Control loop with purely proportional behavior
Compensation for the lag between the electro-
magnetic and magnetic fields in the motor
Control loop with proportional and
differential behavior
Regulates the difference between the position
setpoint and the actual position to 0
Output: speed setpoint
electrically decoupled, electrical isolation
System protection device with phase monitoring
Maximum power which can be dissipated in the
regen circuit
Converts superfluous energy fed back by the
motor during braking (regenerated energy) into
heat.
New start of the microprocessor
Conversion of the analog resolver signals into
digital information
Operation with a periodic change of direction
Ferrite rings for interference suppression
Incremental position output
Control device for regulating the speed, torque
and position of a servomotor
Limits for the rate of change of the speed setpoint
here: electrically conductive connection between
two phases
Regulates the difference between the speed
setpoint and the actual value to 0
Output : current setpoint
Cyclically absolute, serial position output
Device to divert interference on the power supply
cables to PET
Voltage proportional to the actual speed
Temperature-sensitive switch built into the
motor winding
Integral component of a control loop
Output once per turn from incremental encoders,
used to zero the machine
Page 117

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmctendo dd5Pmcprimo drive3

Table of Contents