10 Setup
10.7

Warning messages PMCtendo DD5

Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO
contact remains closed), are indicated in the LED display on the front panel by a coded warning
number. Detailled description see "ASCII command reference"
Number
E/S/A/P
. . .
-
n01
n02
n03*
n04*
n05
n06*
n07*
n08
n09
n10*
n11*
n12
n13*
n14
n15
n16
n17
n18
n19-n31
n32
A
* = these warning messages result in a controlled shut-down of the drive (braking by emergency
stop ramp)
You can find further information on handling errors from page 113 and in the "ASCII
command reference" (part of the setup software's online help system)
Installation manual for PMC tendo DD5/PMCprimo Drive3
Designation
status Messages
status Message
status Message
I²t
regen power
S_fault
response monitoring
supply phase
SW limit switch 1
SW limit switch 2
motion task error
no reference point
PSTOP
NSTOP
motor default values
loaded
expansion card
SinCos feedback
table error
summarized warning
fieldbus-sync
multiturn overflow
reserve
firmware beta version
reset
Explanation
status messages, no error, see p. 94
amplifier is updating the startup configuration
status message, no error, programming mode
I²t threshold exceeded
reached preset regen power limit
exceeded preset following error limit
response monitoring (fieldbus) has been activated
mains supply phase missing
passed software limit switch 1
passed software limit switch 2
a faulty motion task was started
no reference point (Home) set at start of motion task
PSTOP limit-switch activated
NSTOP limit-switch activated
only for ENDAT or HIPERFACE® :discrepancy between
motor number saved in the encoder and the amplifier,
motor default values loaded
expansion card not operating correctly
SinCos commutation (wake & shake) not completed, will
be canceled when amplifier is enabled and wake & shake
carried out
fault according to speed/current table INXMODE 35
summarized warning for n17 to n31
sync is not logged in
max. number of motor turns exceeded
reserve
firmware is an unreleased beta version
RESET is present on input DIGITAL INx