Entrapment Protection - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

Assess Your Gate Site.
1
Design your gate installation so entrapment zones are kept to a minimum, and then install
your HySecurity gate operator.
NOTICE: UL 325 Standard of Safety provides the MINIMUM safety standards. Site, gate hardware usage, and other
conditions may dictate the use of additional safety designs/components. It is up to the gate system designer and
installer to assess appropriate safety design and components above and beyond minimum UL 325 and ASTM F2200
standards. Always check your local area codes and comply with all regulations.
Install NC sensors.
2
Install non-contact sensors (photo eyes) beneath the barrier arm to help prevent the barrier arm from
lowering on a person if standing under the raised arm. HySecurity gates monitor normally closed (NC)
sensors. Wire your NC sensors to SENSOR input terminals (SENSOR 1, SENSOR 2, or SENSOR 3) on
the Smart Touch Controllers.
NOTE: When installing wired edge sensors, the wired edge must be connected to an interface module with an NC output. See
MX3657-01 Rev. D ©2020

Entrapment Protection

Outside
Obstruction Loop
Entrapment Protection
Access
control device
Warning signs
Photo eye
hysecurity.com | 800-321-9947
Reset Loop
Inside Obstruction
Loop
49

Hide quick links:

Advertisement

Table of Contents
loading