HySecurity StrongArm 14F Programming And Operations Manual page 71

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

Installer Menu
0 = Normal operation of Free Exit
CB 0 (OFF)
CLD Disable ELD
1 = Disable Free Exit
EB 0 (OFF)
0 = Normal operation of Free Exit
ELD Backoff
1 = Back off close function
1 = Standard
DL 1 STANDARD
DETECTOR LOGIC
2 & 3 = Quick Close
4 = Full anti-tailgate
RL 1 CLOSE LIM
0 = Disabled
RELAY 1 LOGIC
1 = Close limit active
(1 to 29 available)
R2 6 GATE LOCK
0 = Disabled
RELAY 2 LOGIC
1 to 29 available
R3 1 CLOSE LIM
0 = Disabled
RELAY 3 LOGIC
1 to 29 available
R4 through R11
0 = Disabled
RELAY <n> LOGIC
1 to 29 available
TL 2 (45 SECS)
0 = 0s delay
OPEN TIME ALERT
1 = 15s
2 = 45 second delay
3 = 75s
4 = 105s
5 = 135s
MX3657-01 Rev. D ©2020
Setting Options
Display & Menu Options
Menu Tasks & Explanations
Setting 1 allows an CLD input to disable the
Free Exit Detector (ELD) until the barrier arm
is fully closed. Used in bi-directional traffic
situations.
The default allows normal latch open
operation of the Free Exit detector. The
optional setting of 1, creates an automatic
close function if a vehicle triggers and then
backs off the Free Exit Loop detector.
Determines how the operator responds to a
tail gate notification. See Anti-TailGate Mode
(Closing Logic) on page 93.
NOTE: Does not appear in barrier gate
operators.
Configures the function of the User 1 output
relay. It has the capacity to switch both AC
and DC loads and can be used for high
voltage and/or high current loads. Connect
devices directly to the top of the relay: COM
and either NO and/or NC contacts. Multiple
logic function options exist. Refer to User
Relays – Programming Procedure on page
81.
Configures the function of the User 2 output
relay. It has the capacity to switch both AC
and DC loads and can be used for high
voltage and/or high current loads. Connect
devices directly to the top of the relay: COM
plus NO and NC contacts. Multiple optional
logic function options exist. Refer to User
Relays – Programming Procedure on page
81.
Relay 3 configures the function of the User
3 output relay, which is an electronic relay
with the capacity for switching a DC load
only. In the StrongArm M30/M50, Relay 3
is connected to the gate LED lighting and
does not appear as an option in the Installer
Menu.
Similar to Relay 1 Logic.
NOTE: The Hy8Relay
module option can
be purchased to provide an additional
8 relay terminals. Relay #39 set aside for
Factory Use.
Lets you specify when the relay activates.
The relay turns ON when the software
detects that the gate operator has been
off its close limit for the specified period of
time. With updated software versions, TL
appears in the Installer Menu even without
the User Relay option 8 being utilized.
hysecurity.com | 800-321-9947
STC Wire
Connections
Reset (Center)
Loop
COM or
connection to
HY-5A detector
Free Exit Loop
COM or
connection to
HY-5A detector
User 1 Relay
User 2 Relay
User 3 Relay
COM
NOTE: R4
through RB user
relays appear
on 7-segment
display
User Relay 8
71