Smart Touch Controller Inputs; Stc Terminal Inputs - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

s
t
Mart
ouCh
When using AC power, an LED lights next to any active input.
1. Test the open and close function of the gate before wiring to accessory devices (external control
inputs). This makes it easier to troubleshoot if an unexpected functionality arises.
NOTE: If you are using the operator strictly in a DC capacity, the Smart Touch Controller has a tact button you
can push which lights an LED next to the active inputs. This button is in the bottom left corner of the STC board.
Press the SHOW LEDs push button switch to verify the status of the terminal inputs.
2. All the Smart Touch Controller inputs listed below are shown as a single input. The second wire is
connected to the Common Terminal Bus on the Power Supply Board.
NOTE: The Emergency Close and Fire Dept. Open inputs are an exception and require a +24V input.
The +24V is located on Power Supply Board next to the Common Bus. See illustration on previous page.
stC t
erMinal
WARNING
Use Terminal Inputs 4, 5, 6, and 7 for external control devices. DO NOT connect an external control device to
Input Terminals, 1, 2, or 3 unless the controls are located in clear view of the entire gate area and are being
constantly monitored and supervised.
NOTE: UL 325 2016 sensor input label changes shown in Bold.
No.
Smart Touch
Smart Touch
Terminal
Terminal
UL 325 - 2016
pre-2016
1
Stop Button
Stop Button
2
Open Button
Open Button
3
Close Button
Close Button
4
Remote Open
Remote Open
& Radio Control
& Radio
Control
5
Open/Close
Open/Close
Button
Button
6
Open Partial
Open Partial
78
hysecurity.com | 800-321-9947
C
ontroller
i
nPuts
Smart Touch Controller Inputs Chart
Wire Connections
Normally Closed input. Jumper
to Common if input is not being
used.
Do not use for radio or remote
access controls.
Normally Open Input
Do not use for radio or remote
access controls.
Normally Open Input
For radio/remote open device:
Access the RO from the User
Menu and set to 1. NO Input
Connection for push button or
radio controls.
NOTE: NOT USED on
StrongArm. Terminal is only
used in slide gates. Adjustable
through the Installer Menu from
7 to 99.
StrongArm Programming and Operations
i
nPuts
Commonly used for...
Line of sight, external
stop button or 3-button
station.
Line of sight, external
open button or 3-button
station.
Line of sight, external
close button or 3-button
station.
Remote access control or
radio controls
Singular button device
(multi-function)
Monitored access
controls