1. Connect photo eye wiring.
NOTE: Run a jumper between photo eye -24V (POWER
INPUT) and COM terminals on the Receiver.
2. Turn ON power.
3. Access the Installer Menu and configure SENSOR
setting according to the entrapment area that the
photo eye is monitoring. Refer to table on page 29.
*NOTE: Make sure whichever wired input used (SENSOR 1, 2, or 3) is the
same Sensor # configured through the Installer Menu.
EMX IRB MON Photo Eye
Transmitter
COMMON / NEG. to SENSOR COM
Jumper POWER
INPUT - 24V to COM
CAUTION
DIP switches must be set as shown otherwise the photo eye will not operate correctly. If you receive an Alert,
"!ACTION BLOCKED" "Photo Eye Open" PEO or "Photo Eye Close" PEC, take steps to align the photo eye.
Refer to Photo Eye Alignment Feature on page 104.
124
hysecurity.com | 800-321-9947
: P
e
hoto
ye
Power Supply Board
+24V
CAUTION
Set DIP Switches
1 = OFF
2 = OFF
3 = OFF
4 = ON
+24V
t
B
hru
eaM
S1 0
SENSOR #1 TYPE
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
LIMIT
StrongArm Programming and Operations
(eMx irB Mon)
Installer Menu showing
Sensor 1 set to Eye Open
(Option #4)*
S1 4 (EYE OPEN)
SENSOR #1 TYPE
DRIVE
POWER
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR
COM
DO NOT USE
SENSOR 2
DO NOT USE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
HySecurity
LOCK INTERLOCK
MX000585
VERSION
S/N
EMERG CLOSE
FIRE DEPT OPEN
Smart Touch Controller
LED
DUAL GATE
RADIO OPTIONS
RPM
COM
A
B
COM
OPEN
+24V
+24V
MX3657-01 Rev. D ©2020
RS485
COM
NO
STATUS
S 1
COM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents