Dc Power Supply (Ups) Connections; Ac Power Supply With Hyinverter Ac - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

dC P
s
oWer
Posts
Conduit
aC P
s
oWer
Gate operators equipped with the AC Power Supply with HyInverter AC option are powered by four 12-Volt,
110Ah DC batteries which, when AC power loss occurs, maintain a true Uninterrupted Power Supply (UPS)
system. When the local AC power fails, the UPS back up system continues to move the gate. System features
are covered in the HyInverterAC Installation and Reference Manual shipped with the product and available
online at www.hysecurity.com.
NOTICE: The AC Power Supply with HyInverter AC option is intended for single phase (1 hp) gate operators and
single phase (2 hp) gate operators that use Variable Speed Drives (VFD).
36
hysecurity.com | 800-321-9947
(uPs) C
uPPly
If you have a gate operator with a DC Power Supply unit, you will need to
connect the primary AC input power to the DC Power Supply.
Additional ¾-inch (19 mm) conduit is needed for electrical wiring
interconnections between the gate operator and DC Power Supply
Cabinet. AC input power is connected to the electrical components in
the chassis, and additional wiring is run through conduit to the DC Power
Supply Cabinet.
System features are covered in the DC Power Supply Installation
Instructions supplement shipped with the product and available online at
www.hysecurity.com.
h
uPPly With
onneCtions
i
aC
y
nVerter
Straps
Internal & external wiring not shown.
Drawing is not to scale
StrongArm Programming and Operations
Footman
Loops (2x)
HyInverter AC
Four 12V, 110Ah AGM batteries
MX3657-01 Rev. D ©2020