Installer Menu
PC 0 NO INPUT
0 = Normally Open NO input
PHOTO EYE
1 = Normally Closed NC input
(monitored)
OUTPUT
GC 0 NO INPUT
0 = Normally Open NO input
GATE EDGE
1 = Normally Closed NC input
OUTPUT
(monitored)
TC 1 (INTLOCK)
0 = TIME CLK (Select Time Clock)
TIME CLK/INTLOCK
1 = INTLOCK (Select Open Interlock)
DT 0 FREE EXIT
0 = Disable Free Exit
DISABLE FUNCTION
1 = Disable Close Timer
OR 1 REVERSE
0 = Pause closing only
1 = Enable reversing to open
OUTSIDE OBS LOOP
2 = Ignore and continue closing*
IR 1 REVERSE
0 = Pause closing only
INSIDE OBS LOOP
1 = Enable reversing to open
2 = Ignore and continue closing*
CR 0 REVERSE
0 = Reopen if center loop triggers
CLD Pause Open
1 = Pause only
NOTE: The shaded Installer Menu items do not appear when Build Year is set to 2 (BY 2). Exceptions exist for barrier arms, CRASH
products, operators set to pre-2016 and Usage Class IV provisions.
70
hysecurity.com | 800-321-9947
Setting Options
StrongArm Programming and Operations
Menu Tasks & Explanations
Changes occurring in 2016. See NOTE.
The default setting is for photo eyes with
Normally Close outputs. When set for NC,
the connection is monitored and any short
circuit fault will generate a FAULT 2 (FAL2)
alert. Press the Stop or Reset button to clear.
Changes occurring in 2016. See NOTE.
The default setting is edge sensor with
Normally Closed (NC) output. The optional
setting of 0 requires an (NO) output.
Configures the input at Terminal No. 7 on
the STC to be either for the gate interlock
function, or for an external time clock to
open input. The default setting is (TC_1) for
the interlock function.
Configures Terminal #9 input to disable
either the Free Exit Detector function
or, alternately, the Close Timer function.
The default setting disables the free exit
detector.
NOTE: When set to 0, the free exit is
disabled while the gate rests on it's closed
limit. If the closed limit is not tripped, the
free exit continues to work normally.
The default (1) is for full reversal when the
Outside Obstruction Loop is triggered. A
setting of 0 causes the gate to only pause
when triggered. The gate closure begins as
soon as the loop is clear again. *A setting
of 2 is only available on CRASH barriers
and provides for the most secure facilities
where it is essential that the loop trigger
is completely ignored and the barrier arm
continues closing without pause or reversal.
The default is for full reversal when the Inside
Obstruction Loop is triggered. A setting
of 0 causes the gate to only pause when
triggered. Closure begins as soon as the
loop is clear again. *A setting of 2 is only
available on CRASH barriers and provides for
the most secure facilities where it is essential
that the loop trigger is completely ignored
and the gate continues closing without
pause or reversal.
The default allows the barrier arm to reopen
if the Reset (Center) Loop detector is
triggered during closure of the barrier arm.
A setting of 1 causes the barrier arm to only
pause when triggered. Closure begins as
soon as the loop is clear again.
STC Wire
Connections
COM
+24V
COM
PHOTO EYE
CLOSE
DIRECTION
COM
+24V
COM
EDGE SENSOR
INTERLOCK
OPEN (#7)
COM
DISABLE EXIT
DETECTOR (#9)
COM
OUTSIDE OBS
LOOP (#11)
COM or
connection to
HY-5A detector
INSIDE OBS
LOOP (#10)
COM or
connection to
HY-5A detector
Reset (Center)
Loop
COM or
connection to
HY-5A detector
MX3657-01 Rev. D ©2020