Installer Menu
LT 3 (75 SECS)
0 = 0s delay
LOITERING ALERT
1 = 15s
2 = 45s
3 = 75 second delay
4 = 105s
5 = 135s
SA 0 (OFF)
0 = No network
STC ADDRESS
1 to 99 = Network "drop" address
0 = No network (off)
NE 0 (OFF)
NETWORK SETUP
1 = Network address (on)
ID 0 HYINVERTER
0 = no diagnostics displayed
DIAGNOSTICS
1 = view diagnostics displays
ELD0 RUN MODE
0 = Run mode
EXIT LOOP SET
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
0 = Run mode
ILD0 RUN MODE
IND OBS LOOP SET
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
0 = Run mode
OLD0 RUN MODE
OUT OBS LOOP SET
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
0 = Run mode
RLD0 RUN MODE
RESET LOOP SET
1 = Show frequency
(Shadow Loop Set)
2 = Show call level 0-7
3 = Set Frequency
72
hysecurity.com | 800-321-9947
Setting Options
HYINVERTER INPUT - LINE xxx.x VAC
HYINVERTER TEMP - xxx.xF / xxx.x C
HYINVERTER VOLTS - BATTERY xx.x
VDC HYINVERTER - BATTERY xxx.x %
Menu Tasks & Explanations
Lets you specify when the relay activates.
The relay turns ON when the software
detects that the gate operator has been
off its close limit for the specified period of
time. With updated software versions, LT
appears in the Installer Menu even without
the User Relay option 8 being utilized.
Sets the system address for network
communication. 1 – 99 sets individual poling
addresses.
Refer to HyNet™ literature for more
information.
Menu item appears when SA is not set to
zero (0).
If a system address exists a setting of 1
opens the network configuration menu.
0 = no network communication
1 = allows configuration of network
addresses.
Controls which system diagnostics appear
on the display. With a setting of 1, you can
access the AC Power Supply with HyInverter
AC diagnostic mode. Use the Next or
Previous buttons, on the gate operator's
keypad, to view the diagnostics on the STC
display.
NOTE: These same diagnostics appear on
the AC Power Supply with HyInverter AC
display in a constant scrolling format.
Controls the HY-5B Free Exit loop detector.
Controls the HY-5B Inside Obstruction Loop
detector.
Controls the HY-5B Outside Obstruction
Loop detector.
Controls the HY-5B Shadow/Reset Loop
detector.
StrongArm Programming and Operations
STC Wire
Connections
User Relay 8
RS-485. Involves
additional
hardware &
software.
RS-485. Involves
HyNet™ &
software.
AC Power Supply
with HyInverter
AC to STC
(Modbus RTU
communication
protocol via
RS-485.)
HY-5B
HY-5B
HY-5B
HY-5B
MX3657-01 Rev. D ©2020