Installation Instructions

MX3635-01 Rev. D
Linear actuators for large, heavy swing gates and swing gates subject to extreme peak winds
Models
HydraSwing 40F
4,000 lb (1,814 kg)
HydraSwing 40
4,000 lb (1,814 kg)
HydraSwing 40 Twin
4,000 lb (1,814 kg)/leaf
HydraSwing 40F Twin
4,000 lb (1,814 kg)/leaf
HydraSwing 80F
8,000 lb (3,629 kg)
HydraSwing 150
15,000 lb (6.804 kg)
10-15 seconds
15-20 seconds
15-20 seconds
10-15 seconds
15-25 seconds
20-30 seconds
MX3635-01

Advertisement

Table of Contents
loading

Summary of Contents for HySecurity HydraSwing 40F

  • Page 1: Installation Instructions

    10-15 seconds HydraSwing 40 4,000 lb (1,814 kg) 15-20 seconds HydraSwing 40 Twin 4,000 lb (1,814 kg)/leaf 15-20 seconds HydraSwing 40F Twin 4,000 lb (1,814 kg)/leaf 10-15 seconds HydraSwing 40s HydraSwing 80F 8,000 lb (3,629 kg) 15-25 seconds HydraSwing 150 15,000 lb (6.804 kg)
  • Page 2 Locate and install the HydraSupply within 50 feet (6.1 m) of the HydraSwing gate operator. (34 cm) Remember to order hose through HySecurity! Flange Unistrut U-bolt NOTE: Order hose through HySecurity. See CAUTION. In addition to conduit length, make sure 1⅞” Wall or post-mount the 30¾” (78 cm) (5 cm)
  • Page 3 See pages 4 and 5. 41”L x 20½” W (104 x 52 cm) optional base extension adds an additional 4 inches to the width Drawings NOT to Scale © 2017 www.hysecurity.com HydraSwing Installation and Assembly MX3635-01 Rev. D Page 3...
  • Page 4 Mounting holes shared with cylinder is strained and will lessen its life and void the brake cylinder bracket Inswing mount shown: Center hinge Drawings NOT to Scale Warranty. © 2017 www.hysecurity.com HydraSwing Installation and Assembly MX3635-01 Rev. D Page 4...
  • Page 5 Degree of Swing Yf ± ¼” (Cylinder housing plus Xf dimension) 12” (30.5 cm) 11” (28 cm) 5” (12.7 cm) 13½” (34.3 cm) Fully extended cylinder: 62½ inches (159 cm) © 2017 www.hysecurity.com HydraSwing Installation and Assembly MX3635-01 Rev. D Page 5...
  • Page 6: Power Connection

    POWER RS485 STOP BUTTON DO NOT USE OPEN BUTTON Verify you have the proper input CHARGER CLOSE BUTTON HySecurity gate operators are intended REMOTE OPEN AND AC LOSS RADIO CONTROL HySecurity voltage and make sure the motor OPEN/CLOSE OPEN PARTIAL for permanent installation.
  • Page 7: Complete The Installation

    If you notice fluid leakage, stop gate travel immediately and use Brake manifold the hand pump. High capacity hand pump: 80F & 150 models Run mode Drawings NOT to Scale © 2017 www.hysecurity.com HydraSwing Installation and Assembly MX3635-01 Rev. D Page 7...