This check list is provided by HySecurity and is to be used after installing a StrongArm barrier gate operator.
1. Before checking the items in this list, make sure power is turned OFF at the main power
disconnect and the operator's control box power switch is also in the OFF position.
2. Check the following:
‰ Electric motor and transformer wired properly.
‰ Incoming power supply voltage matches the label on the motor.
‰ Gate operator barrier arm is level.
‰ Operator is labeled as appropriate for both the type and UL usage class of the gate.
Make sure the phase, hertz, and power match the operator and its labeling:
‰ 1 Ø
‰ 3 Ø
‰ DC-24V
‰ 115 VAC
‰ Power cable run to the operator is of sufficient wire size to handle starting current.
‰ NEC/NFPA ground rod is installed.
‰ All wires and cables are clear of moving parts (limits, valves, power, etc.).
‰ Breather cap has been installed, replacing the Vent Plug in the pump.
‰ Oil level checked.
‰ All chassis bolts are tight.
‰ Pinch points protected.
‰ 6 foot (1.8 m) minimum distance to access controls.
‰ Pedestrian gate exists.
‰ Necessary loops are in place and properly connected to vehicle detectors.
NOTE: Be sure to read the Installation Instructions and the Programming and Operations Manual that accompany the operator. The
product literature explains, in detail, many aspects about installation, programming, maintenance and safety procedures. If you have
further questions, please contact Technical Support at 800-321-9947.
3. Cycle test the barrier arm by pressing the CLOSE and OPEN buttons. Allow the arm to continue
traveling throughout its entire range while you or your assistant check the following:
• Gate handing is set correctly. See product literature for information on gate handing.
• Limit switches are adjusted properly.
• Pressure relief valve is properly set. Refer to the yellow tag inside the operator or refer to the
product literature, Adjust Pressure Relief Valve on page 44.
4. External entrapment protection sensors, accessories, and options have been installed tested and
comply with UL 325 Standard of Safety.