HySecurity StrongArm 14F Programming And Operations Manual page 83

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

Setting
19
Flasher Relay
20
Free Exit Loop Vehicle Detector
output
21
Inside Obstruction Vehicle Detector
output
22
Center Loop Detector output
23
External Latching gate Lock Output
(Prison Lock)
24
Gate at Partial Open Position
25
DC Power OK Alert
26
Free Exit Vehicle Detector Pulse
27
Not Open (requires AC power)
28
Flasher (requires AC power)
29
Set aside for Factory Use
30
Arm Breakaway
31
Warn Operate Run
32
Partial Open Pulse
33
Inbound Transient/Lot Output
34
Outbound Transient/Lot Output
35
Inbound Tenant Output
MX3657-01 Rev. D ©2020
Performance
Flashes lights once per second. The relay is constantly
pulsing except when the open limit switch is triggered.
* Preferred connection is Relay 3, a solid state relay (except
on Crash). On Crash gate operators, Relay 3 is unavailable
because it is hard-wired for the LED barrier arm lights.
Active when the Free Exit Loop is tripped.
Active when the Inside Obstruction loops is tripped.
Active when the Reset/Center/Shadow loop detector is
tripped.
Activates when the Lock Interlock Input (Terminal No. 22)
is active at the start of an Open cycle and remains on until
the Lock Interlock releases or 10 seconds elapse, whichever
happens sooner. Also, activates a Close cycle and releases 1
second after reaching the Close limit.
Active when the partial open position is reached or
exceeded. Not used in StrongArmCrash.
Deactivates when the software detects a low battery voltage
(below 21VDC, but greater than 18VDC) for a duration of
2 seconds or more. To slow battery drain, accessory power
loads are shed.
Activates when the Exit Loop Detector is tripped and causes
a 250mS pulse output to occur.
When AC power is detected, this relay activates when the
gate in NOT on the open limit. If AC power fails, or the gate
is on the open limit, the relay is deactivated.
Controls flashing lights that pulse 500ms per second. The
relay is constantly activating except when the open limit
switch is triggered or AC power fails.
HySecurity Testing Only
Only used on StrongArm and StrongArmPark DC and
activates if the breakaway arm switch is tripped.
Relay is active while warn before and motor running.
Relay pulses when partial open activated and when partial
open limit reached. Often used at a sequential gate site.
N.O. Input. The relay outputs a 250ms pulse used to
increment the transient and total vehicle counts. Refer
to the HySecurity Parking supplement for more detailed
information.
N.O. Input. The relay outputs a 250ms pulse used to
decrement the transient and total vehicle counts. Refer
to the HySecurity Parking supplement for more detailed
information.
N.O. Input. The relay outputs a 250ms pulse and increments
the tenant counter when the Tenant User input is activated
and OALD, then CLD, are tripped and released. This activity
signals a prepaid customer has entered the facility.
STC Inputs & Wiring
Description
hysecurity.com | 800-321-9947
Wire
Connection
Relay 1 or 2*
(Relay 3)
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Do not use
Relay 1 or 2
Relay 1 or 2
R1 and R2, R4
through R11
TRANSIENT
USER
R1 and R2, R4
through R11
TRANSIENT
USER
R1 and R2, R4
through R11
TENANT USER
83