Smart Touch: Photo Eye / Reflecti-Guard (Rg-R) - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

s
t
Mart
ouCh
1. Connect photo eye wiring.
NOTE: Run a jumper between photo eye -24V and CM terminals.
2. Turn ON power.
3. Access the Installer Menu and configure SENSOR setting
according to the entrapment area that the photo eye is
monitoring. Refer to table on page 29.
CAUTION
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes. The
sensor becomes actively powered when the gate
operator's motor runs.
Power Supply
Board
+24V
Reflecti-GUARD Photo Eye
NOTE: If you receive an Alert, "!ACTION BLOCKED" "Photo Eye
Open" PEO or "Photo Eye Close" PEC, take steps to align the photo
eye. Refer to Photo Eye Alignment Feature on page 104.
Wiring HySecurity Sensors: Smart Touch
MX3657-01 Rev. D ©2020
: P
e
hoto
ye
Connect NC relay
wire to SENSOR 1,
2, or 3.
To pull 3 wires instead of
4, jumper, PWR Relay to
CM terminal
/ r
-G
efleCti
DRIVE
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
10
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
SHADOW/RESET
12
VEHICLE DETECTOR
SENSOR 1
14
SENSOR
COM
15
16
DO NOT USE
17
SENSOR 2
18
DO NOT USE
19
SENSOR 3
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RPM
COM
hysecurity.com | 800-321-9947
(rG-r)
uard
Installer Menu
showing Sensor 1
set to Eye Open
S1 0
(Option #4)
SENSOR #1 TYPE
S1 4 (EYE OPEN)
SENSOR #1 TYPE
RS485
POWER
COM
NO
STATUS
HySecurity
MX000585
VERSION
S/N
RADIO OPTIONS
S 1
A
B
COM
OPEN
+24V
+24V
COM
127