HySecurity StrongArm 14F Programming And Operations Manual page 68

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

Installer Menu
0 = AC powered charger
CH 0 (AC)
CHARGER TYPE
1 = Solar powered charger
FO 0 (DISABLED)
0 = disabled
FIRE DEPT OPEN
1 = enabled
OC 0 (DISABLED)
0 = disabled
EMERGENCY CLOSE
1 = enabled
SE 2
1 = maximum sensitivity
IES SENSITIVITY
2 = moderate (default)
(Not used in
9 = lowest sensitivity
StrongArm models)
SS 0
0 = (off) Stop and reverse for 2s
IES STOP ONLY
1 = (on) stop only
(Not used in
StrongArm models
0 = none
LC 0
LEAF DELAY CLOSE
1 to 7
0 = none
LO 0
LEAF DELAY OPEN
1 to
RT 0 (60 SECS)
0 = 60 Seconds max run
MAXIMUM RUN
1 = 300 Seconds max run
TIME
PO 0 (OFF)
0 = none
7 to 99 seconds
PARTIAL OPEN
68
hysecurity.com | 800-321-9947
Setting Options
StrongArm Programming and Operations
Menu Tasks & Explanations
Does not appear on an AC-powered
operator. The menu item only appears when
using the DC Charger unit and designates
the charger type.
Provides the Fire Dept. Open input. When
set to 1, the open signal received by the
operator overrides all photoelectric eyes and
edge sensors, and opens the gate. Pressing
the Open or Reset button is required before
the gate can be closed.
Enables the Emergency Close input. When
set to 1, the constant hold close overrides
vehicle detectors, photo eyes and edge
sensors, and closes the gate. Pressing the
Reset button once or the Open button twice
is required before the gate will open.
Adjusts the sensitivity of the inherent
entrapment sensor. Available settings are
1-9 with 9 being the least sensitive.
A setting of 0, stops the gate and then
reverses its direction of travel for 2 seconds.
To stop gate travel with no reversal, the
optional setting 1 can be selected if the
gate operator is at a Usage Class IV site and
assigned a UC 4 classification.
Only appears if the gate operator is set up as
a Primary or a Secondary. Available settings
are 1 to 7. Each numerical increment adds ½
second, to a maximum of 3 ½ seconds time
delay, before the operator activates when
commanded to close.
Only appears if the gate operator is set up as
a Primary or a Secondary. Available settings
are 1 to 7. Each numerical increment adds
1/2
second (with a maximum of 3
time delay following a command to open
before the operator activates.
Allows an optional setting of 300 seconds
if changed to [RT 1] as opposed to the
maximum run timer default setting of
60 seconds.
Activates the partial open input and allows
an adjustable distance by setting the open
duration. The available time settings are 7 to
99 seconds. The default setting [PO 0] leaves
this input inactive.
STC Wire
Connections
+24V
Fire Dept Open
(#24)
+24V
EMERG CLOSE
(#23)
N/A
N/A
1/2
seconds)
N/A
Open Partial
#6
COM
MX3657-01 Rev. D ©2020