Page 8
Contents Parts & Limited Warranty Contents - 4 SlideSmart Installation and Reference Manual Revision C...
Page 9
Intelligent Features: Smart DC ControllerTM Robust Power Finesse UPS backup and Solar ready Menus and User relays Independent adjustment for open and close gate speeds Intelligent Inherent Entrapment Sensor (IES) Improved Liquid Crystal Display (LCD) USB communications port START software and diagnostics Intro-2 SlideSmart Installation and Reference Manual Revision C...
Page 10
Technical Support SlideSmart Components Revision C Introducing SlideSmart DC Intro-3...
Page 11
Installer's Check List Smart Touch Analyze and Retrieve Tool Reference Smart Touch Analyze and Retrieve Tool Intro-4 SlideSmart Installation and Reference Manual Revision C...
Page 13
Important Safety Instructions Identifying Gate Operator Category and Usage Class → Revision C Safety Requirements...
Page 14
Important Safety Instructions → Secondary Entrapment Protection Sensors → → → SlideSmart Installation and Reference Manual Revision C...
Page 15
Important Safety Instructions Revision C Safety Requirements...
Page 16
Important Safety Instructions Hazardous Waste Regulations SlideSmart Installation and Reference Manual Revision C...
Page 17
Secondary Entrapment Protection Sensors PHOTOELECTRIC EYES: EDGE SENSORS: SENSOR SECURITY: SENSOR FUNCTION and COMMUNICATION: UL 325 LISTING: Important Safety Instructions Revision C Safety Requirements...
Page 19
Secondary Entrapment Protection Sensors Revision C Safety Requirements...
Page 20
Emergency Stop Button Emergency Stop You DO NOT need to turn AC power off to manually push the gate. 1. Make sure the gate is not moving. 2. Flip the DC power switch on. 3. Clear any faults by pressing STOP or RESET. SlideSmart Installation and Reference Manual Revision C...
Page 21
Safety Notices AFETY OTICES The following four levels of safety notices are used where applicable within this manual; each notice contains information specific to the situation. DANGER Indicates death or serious injury will occur if the hazardous situation is not avoided. WARNING Indicates death or serious injury could occur if the hazardous situation is not avoided.
Page 22
Common Industrial Symbols S-10 SlideSmart Installation and Reference Manual Revision C...
Page 23
230 volts, 1.5 amps, 50/60 Hertz 230 volts, 1.5 amps, 50/60 Hertz ½ ½ Motor: Motor: Gate speed: 1ft/s Gate speed: 2ft/s Gate weight: Maximum 1500lbs (675kg) Gate weight: Maximum 1000lbs (450kg) Note:For SlideSmart DC Solar operators, refer to www.hysecurity.com Revision C Installation...
Page 24
Site Overview & Planning Chain 6.4" #40 Roller (16.3cm) Gate Area cut out 5" (26.7cm) conduit 21" (53.3cm) 6.9 x 12" (17.5 x 30.5cm) 1.6" (4.1cm) Slotted holes (4x) for Concrete 10.38" concrete anchors: (26.4cm) ½ - 13 x 3½" 19"...
Page 25
Site Overview & Planning Gate Chain to Gate 3¾" (9.5cm) Ideal distance = Minimum distance = 2½" (5cm) Cut out if rear Chain install height ¾" (19.7cm) Grade level Concrete pad Side View Concrete Pad Mount Conduit cut outs Revision C Installation...
Page 26
Site Overview & Planning Public Side Physical stop (2x) Chain Secure Side Chain bracket (2x) Several different ways to mount the SlideSmart operator exist. A few are shown here. Note: For more detailed drawings, refer to the Installation Configurations in the Appendix. Chain Optional 50Ah...
Page 27
Site Overview & Planning Sprocket Chain Target magnet position between idler wheel and sprocket when gate is fully closed. See Figure 1-20. Idler wheel Target magnet View shows how to feed chain over sprocket and idler wheel for a rear installation. End of the gate Idler Post Posi on post to maintain a minimum...
Page 28
Unpacking the Operator Lock Cover Base plate SlideSmart Installation and Reference Manual Revision C...
Page 29
Concrete Pad Mount Left hand gate Chain to Gate (shown in full CLOSE 3¾" (9.5cm) Ideal distance = position) Minimum distance = 2½" (5cm) Gate Chain resides Gate support Chain inside gate posts 6.4" #40 Roller support posts (16.3cm) parallel with the gate.
Page 30
Gate Bracket and Chain Installation Public Side Secure Side 7¾" (19.7cm) SlideSmart Installation and Reference Manual Revision C...
Page 31
Gate Bracket and Chain Installation Sprocket Idler wheel Keep chain horizontal to the ground. Target sensor (RH gate) Target sensor (LH gate) SIDE VIEW CORRECT INSTALLATION Chain to gate Ideal distance = 3¾" TOP VIEW (9.5cm) Too close to gate INCORRECT CORRECT INCORRECT...
Page 32
Gate Bracket and Chain Installation Connect red battery wire Turn DC power ON Note:Programming the Setup Menu is usually a one-time occurrence unless factory defaults are reinstated through the Installer Menu. The RESET and MENU buttons do not function during the initial configuration of the Setup Menu.
Page 33
Gate Bracket and Chain Installation To navigate through To choose what is on To navigate between To edit the Menu the SELECTIONS the display menus UC 0 USAGE CLASS OPEN CLOSE STOP MENU RESET PREV NEXT SELECT SH 0 GATE HANDING CLOSE MENU OPEN...
Page 34
NEXT SELECT Installing the Target Magnet NO AC POWER flashes after the gate status display if the Note: AC power has not been connected or the lower power switch is turned off. HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET...
Page 35
Gate Bracket and Chain Installation Installing the Target Magnet NOTE: Only one magnet is required. Two target sensors are provided for LH & RH gate applications, but only one sensor is used. Mark the chain Figure 1-17. 1. With the gate CLOSED, mark the chain link directly across from target sensor that is closest to the trailing edge of the gate.
Page 36
Gate Bracket and Chain Installation Establishing the OPEN & CLOSE Limits Roller chain sprocket Position of the target magnet when the gate is Trailing edge of gate fully closed. (Gate shown in full CLOSE position) Idler wheel Target Second target sensor sensor is not used (LH gate)
Page 37
Gate Bracket and Chain Installation OPEN Position of the Chain motion target magnet when the gate is fully closed. OPEN Revision C Installation 1-15...
Page 38
Gate Bracket and Chain Installation 1-16 SlideSmart Installation and Reference Manual Revision C...
Page 39
Installing the Earth Ground Chapter 2 Standard for the Installation of Lightning Protection Systems Revision C Power...
Page 40
Installing the Earth Ground Lug nut New site Existing site 3 ft Consult local codes for proper Wiring 115VAC Power Wiring 230VAC Power depth. Ground wire and lug nut SlideSmart Installation and Reference Manual Revision C...
Page 41
Wiring AC Power Place the power switches in the OFF position. WARNING DO NOT connect the 115VAC service outlet to 230VAC power supply wires! To use the 115VAC service outlet on a 230VAC installation, the electrician needs to run an extra neutral wire to the operator from the power source and wire the service outlet per code.
Page 42
Wiring AC Power AC Power 14 gauge wire 12 gauge wire 10 gauge wire Note: SlideSmart Installation and Reference Manual Revision C...
Page 43
Wiring AC Power Wiring 115VAC Power AC Power 14 gauge wire 12 gauge wire 10 gauge wire Note: Voltage selector switch set to 230V. Revision C Power...
Page 44
Using A Solar Powered Operator Installing Photoelectric Sensors For Secondary Entrapment Protection Only SlideSmart Installation and Reference Manual Revision C...
Page 45
Using A Solar Powered Operator Important Considerations for DC-powered Operators Minimum Minimum 10W Panel 10W Panel Minimum 20W Panel Two 12V panels in series connect to gate operator One 24V panel connects to gate operator Revision C Power...
Page 46
Using A Solar Powered Operator Installing the Extended Battery Backup Kit Programming the Initial Setup Menu Control Box DC Battery & Motor switch (OFF) Red spade connector DC Solar Panel switch (OFF) Input & ground wires SlideSmart Installation and Reference Manual Revision C...
Page 47
Using A Solar Powered Operator Example of Peripheral Amp Draw COM MON HY-5A TERMINALS FREE EXIT HY-5A INSIDE LOOP STOP OPEN CLOSE OPEN P ARTIAL HY-5A OPEN OUTSIDE LOOP CLOSE EXIT LOOP BLOCK EXIT IN OBS LOOP OUT OBS HY-5A LOOP CENTER LOOP CENTER...
Page 48
The number of amps that the peripherals draw coupled with the gate travel during the day, determines the solar panel size needed. NOTE: HySecurity provides a 50Ah battery option for sites where high gate travel and inclement weather are an issue. For sites of this nature, consider a 40W system. A 40W system doubles the feet of gate trave/day that is shown in the chart above.
Page 49
Important Considerations for DC-powered Operators Hazardous Materials and Proper Disposal Revision C Power 2-11...
Page 50
Important Considerations for DC-powered Operators Post-mounted operator with base extension 50Ah batteries Posts not included in kit Accessory tray Access window 8Ah battery Screws (4x) Wire ties Control box 8Ah battery Hazardous Materials and Proper Disposal 2-12 SlideSmart Installation and Reference Manual Revision C...
Page 51
Important Considerations for DC-powered Operators Black Blue Post-mounted operator with 50Ah batteries base extension Accessory tray HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER OPEN CLOSE STOP MENU RESET PREV NEXT SELECT...
Page 52
Important Considerations for DC-powered Operators 2-14 SlideSmart Installation and Reference Manual Revision C...
Page 53
Initial Setup Chapter 3 Revision C Display and Menu Options...
Page 54
Initial Setup Programming the Initial Setup Menu Establishing the OPEN & CLOSE Limits Installing the Target Magnet Power DC Power Switch AC Power Switch Note:If the target magnet is not detected by the operator, “ALERT 15 - NO TARGET” or “LEARN OPEN” appears on the display.
Page 55
Initial Setup enter navigate Using the Smart DC Controller Buttons in RUN Mode Smart DC Controller Troubleshooting CT 0 (OFF) CLOSE TIMER CLOSE MENU OPEN STOP RESET NEXT SELECT PREV Revision C Display and Menu Options...
Page 56
Run Mode HYSECURITY HYSECURITY HYSECURITY GATE CLOSED GATE STOPPED GATE OPEN OPEN CLOSE STOP MENU RESET OPEN CLOSE STOP MENU RESET OPEN CLOSE STOP MENU RESET PREV NEXT SELECT NEXT SELECT PREV NEXT SELECT PREV SlideSmart Installation and Reference Manual...
Page 57
Run Mode above Using the Smart DC Controller Buttons In Menu Mode Smart DC Controller Troubleshooting HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Note Revision C Display and Menu Options...
Page 58
Run Mode SOFTWARE VERSION H5.## DUAL GATE <MASTER> OT <15>D SLIDESMART DC20 <LEFT> HAND UC <2> Identifying Gate Operator Note USAGE CLASS Category and Usage Class BT <0> STANDARD BATTERY D <32>.0 VDC BATTERY VOLTAGE CC<002600> CYCLE COUNT Note: User Menu Installer CT 0 (OFF) Menu...
Page 59
User Menu Using the Smart DC Controller Buttons In Menu Mode CT 0 (OFF) CLOSE TIMER Note:To bypass the operator status displays and access the User Menu, you can press the MENU button OPEN CLOSE STOP MENU RESET twice. PREV NEXT SELECT Using the Smart DC Controller Buttons In Menu...
Page 60
User Menu CT 0 (OFF) CLOSE TIMER Note:Keep the close time at zero if gate personnel operate OPEN CLOSE STOP MENU RESET the gate or the owner plans to use a remote control. PREV NEXT SELECT SlideSmart Installation and Reference Manual Revision C...
Page 61
User Menu Smart DC Controller Troubleshooting HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER Note:A date or time field must be blinking before OPEN CLOSE STOP MENU RESET it can be changed.
Page 62
User Menu AP 0 AC LOSS UPS FAIL OPEN AP 1 AC LOSS UPS FAIL CLOSE AP 2 AC LOSS AUTO OPEN AP 3 AC LOSS NO CLOSE TIMER User Menu AP 0 (AC LOSS) UPS FAIL OPEN Using the OPEN CLOSE STOP...
Page 63
User Menu LD 5 LCD CONTRAST OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Revision C Display and Menu Options 3-11...
Page 64
User Menu 3-12 SlideSmart Installation and Reference Manual Revision C...
Page 65
User Menu Revision C Display and Menu Options 3-13...
Page 66
User Menu 3-14 SlideSmart Installation and Reference Manual Revision C...
Page 67
Installer Menu Using the Smart DC Controller Buttons In Menu Mode. HYSECURITY GATE CLOSED Note:The menu items, Usage Class, Gate Handing, and Gate Weight must be configured before the OPEN CLOSE STOP MENU RESET operator will function. Refer to PREV...
Page 68
Installer Menu HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER CLOSE MENU OPEN STOP RESET SELECT PREV NEXT LL 0 (OFF) LEARN LIMIT OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Establishing the OPEN & CLOSE Limits...
Page 69
Installer Menu HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) SlideSmart DC 15 CLOSE TIMER OPEN CLOSE STOP MENU RESET SlideSmart DC 10F PREV NEXT SELECT Note:Certain speeds are allowed only when the LL 0 (OFF) operator’s Usage Class is set appropriately.
Page 70
Installer Menu SE 2 IES SENSITIVITY OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Typical Opera on Installer Menu: IES Se ng = 2 Ini al IES threshold (First gate cycle only) Motor current threshold (at IES Se ng 2) Motor current (under typical opera ng condi ons)
Page 71
Installer Menu HYSECURITY GATE CLOSED Gate design OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Gate condition CT 0 (OFF) CLOSE TIMER OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Gate maintenance LL 0 (OFF) LEARN LIMIT OPEN CLOSE STOP...
Page 72
Installer Menu HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Note:When you press SELECT to accept FD 1, the factory settings are reinstated immediately and the menu display returns to the initial Setup Menu.
Page 73
Installer Menu HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER OPEN CLOSE STOP MENU RESET PREV NEXT SELECT LL 0 (OFF) LEARN LIMIT STOP OPEN OPEN CLOSE STOP MENU RESET CLOSE OPEN...
Page 74
Installer Menu 3-22 SlideSmart Installation and Reference Manual Revision C...
Page 75
Installer Menu Revision C Display and Menu Options 3-23...
Page 76
Installer Menu 3-24 SlideSmart Installation and Reference Manual Revision C...
Page 77
Installer Menu Revision C Display and Menu Options 3-25...
Page 78
Installer Menu 3-26 SlideSmart Installation and Reference Manual Revision C...
Page 79
Installer Menu Revision C Display and Menu Options 3-27...
Page 80
Installer Menu 3-28 SlideSmart Installation and Reference Manual Revision C...
Page 81
Installer Menu Revision C Display and Menu Options 3-29...
Page 82
Installer Menu 3-30 SlideSmart Installation and Reference Manual Revision C...
Page 83
Chapter 4 Revision C Smart DC Controller...
Page 84
Overview of the Smart DC Controller Smart DC Controller Troubleshooting NOTE: Amp Draw & Accessories connected to 24VDC COM MON HY-5A TERMINALS FREE EXIT HY-5A INSIDE LOOP STOP OPEN CLOSE OPEN P ARTIAL HY-5A OPEN OUTSIDE LOOP CLOSE EXIT LOOP BLOCK EXIT IN OBS...
Page 85
Overview of the Smart DC Controller Terminal Input Name Revision C Smart DC Controller...
Page 86
Overview of the Smart DC Controller Installing Standard 11-Pin Box Type Vehicle Detectors Sensitivity dial adjustment Status LED Standoff Supports Loop wire (Inset into the connections holes in the Control Box.) Front View Rear View SlideSmart Installation and Reference Manual Revision C...
Page 87
Overview of the Smart DC Controller Installing Vehicle Detectors and Loops Be careful to align the six detector pins into the socket correctly Revision C Smart DC Controller...
Page 88
Overview of the Smart DC Controller Installer Menu Setting Options (Bold - Default) Display Meaning 1 = Enable reverse to open 1 = Enable reverse to open 1 = Standard ( Vehicle Detector Configuration and Quick Close Mode Selection SlideSmart Installation and Reference Manual Revision C...
Page 89
Overview of the Smart DC Controller Installing Photoelectric Sensors For Secondary Entrapment Protection Only five times more power Installing Vehicle Detectors and Loops Revision C Smart DC Controller...
Page 90
Overview of the Smart DC Controller PIN 2 PIN 1 24VAC or 24VDC Connect detector to match its voltage rating Inside Outside Free Exit Obstruc on Obstruc on Center Loop Detector Loop Detector Loop Detector Loop Detector The center loop serves no gate function but the detector can be used as an arming loop when used in conjunction...
Page 91
Connecting Accessory Devices COMMON HY-5A TERMINALS FREE EXIT Mul -colored LED indicates power and gate Access controls HY-5A status. (Ex. Card reader, keypad) HY-5A RS232 INSIDE LOOP STOP RS485 OPEN ethernet CLOSE OPEN P ARTIAL Photo eye N.O. HY-5A connects to either OPEN OUTSIDE LOOP EYE OPEN...
Page 92
Connecting Accessory Devices OPEN STOP OPEN CLOSE CLOSE OPEN P ARTIAL OPEN CLOSE STOP EXIT LOOP BLOCK EXIT IN OBS LOOP OUT OBS Push Bu on Sta on LOOP CENTER LOOP EDGE + 24 V EMERG OPEN SHOW LEDs 4-10 SlideSmart Installation and Reference Manual Revision C...
Page 93
Connecting Accessory Devices Name Description Note: Revision C Smart DC Controller 4-11...
Page 94
Connecting Accessory Devices Name Description Note: 4-12 SlideSmart Installation and Reference Manual Revision C...
Page 95
Power Requirements Chapter 5 + 24 V EMERG OPEN SHOW LEDs USB Port Connection for Master/Slave pair AC Power - Dual Operators 14 gauge wire 12 gauge wire 10 gauge wire Revision C Bi-parting Gate Systems...
Page 96
Master and Slave Wiring Connections Master Slave EXIT EXIT LOOP LOOP BLOCK BLOCK EXIT EXIT IN OBS IN OBS LOOP LOOP OUT OBS OUT OBS LOOP LOOP CENTER CENTER LOOP LOOP EDGE EDGE + 24 V + 24 V EMERG EMERG OPEN OPEN...
Page 97
Master and Slave Menu Setup HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER OPEN CLOSE STOP MENU RESET PREV NEXT SELECT Note:For proper operation, you must set the other gate operator as SLAVE.
Page 98
Master and Slave Menu Setup SlideSmart Installation and Reference Manual Revision C...
Page 99
Connecting a Radio Receiver for Remote Open Chapter 6 EDGE + 24 V EMERG OPEN SHOW LEDs Shows connec ons for Remote Open and Gate Edge (dashed line). Power Two Channel Radio Receiver Note:This terminal is the same as the input terminal labeled RADIO OPEN along the left edge of the Smart DC Controller.
Page 100
Installing a MagLock or Solenoid Lock Overview of the Smart DC Controller SlideSmart Installation and Reference Manual Revision C...
Page 101
Installing a MagLock or Solenoid Lock A ach the power wire from the lock to the appropriate power spade. STOP OPEN CLOSE OPEN P ARTIAL OPEN CLOSE Note:Connect to NO on USER 1 EXIT LOOP RELAY if installing a Solenoid lock. BLOCK EXIT IN OBS...
Page 102
Installing a MagLock or Solenoid Lock A ach the power lead from the lock to the 24VAC power spade. STOP OPEN CLOSE OPEN P ARTIAL OPEN CLOSE EXIT Note:Connect to NO on USER 1 LOOP BLOCK RELAY if installing a Solenoid lock. EXIT IN OBS LOOP...
Page 103
Installing a MagLock or Solenoid Lock HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT CT 0 (OFF) CLOSE TIMER OPEN CLOSE STOP MENU RESET PREV NEXT SELECT LL 0 (OFF) LEARN LIMIT OPEN CLOSE STOP MENU RESET...
Page 104
Installing Vehicle Detectors and Loops Loop Configurations: Rules to Follow for Security Gate Applications: Twist Like This Twist lead-in at least 10 turns per foot Not Like This Like This SlideSmart Installation and Reference Manual Revision C...
Page 105
Installing Vehicle Detectors and Loops Detector Logic Loop Diagnostics Revision C Reference...
Page 106
Installing Vehicle Detectors and Loops PUBLIC SIDE This layout illustrates a bi-direc onal traffic system with ACCESS CONTROL DEVICE ENTER EXIT controlled access entry (card (Card reader, etc.) reader, radio control, etc.) and a free exit gate. The gate’s closure me is determined by the number of seconds entered in the CLOSE TIMER display found in the...
Page 107
Installing Photoelectric Sensors For Secondary Entrapment Protection Only Public Side Photo eye Secure Side Photo eyes Photo eye Revision C Reference...
Page 108
Installing Photoelectric Sensors For Secondary Entrapment Protection Only Photo Eye Open OPEN Direction Photo Eye Close CLOSE Direction EXIT LOOP BLOCK EXIT IN OBS LOOP OUT OBS LOOP CENTER LOOP EDGE Photo Eye COM terminal Photo Eye +24 VDC + 24 V EMERG OPEN SHOW...
Page 109
Installing Photoelectric Sensors For Secondary Entrapment Protection Only Alignment: Table 3-1 "Smart DC Controller - User Menu Functions" on page 3-12 Notes about retro-reflective systems: Revision C Reference 6-11...
Page 110
Using Photoelectric Sensors Instead of Vehicle Loops Installing Photoelectric Sensors For Secondary Entrapment Protection Only OPEN CLOSE EXIT Photo Eye connections for LOOP Free Exit detectors BLOCK EXIT Photo Eye connections for IN OBS Inside Obstruction detectors LOOP OUT OBS Photo Eye connections for LOOP Outside Obstruction detectors...
Page 111
Using Photoelectric Sensors Instead of Vehicle Loops PUBLIC SIDE This layout illustrates a bi-direc onal traffic system with ACCESS CONTROL DEVICE ENTER EXIT controlled access entry (card (Card reader, etc.) reader, radio control, etc.) and photo eyes used as vehicle Placement of detectors.
Page 112
Installing Gate Edge Sensors Photo Wall or fence edge Upright post edge Gate edge Photo eye 6-14 SlideSmart Installation and Reference Manual Revision C...
Page 113
Installing Gate Edge Sensors Edge Sensor STOP OPEN CLOSE OPEN P ARTIAL OPEN CLOSE EXIT LOOP BLOCK EXIT IN OBS LOOP OUT OBS LOOP CENTER LOOP Edge Sensor EDGE + 24 V EMERG OPEN SHOW LEDs Shows connec ons for Gate Edge and Remote Open.
Page 114
Smart DC Controller Troubleshooting Smart Touch Analyze and Retrieve Tool 6-16 SlideSmart Installation and Reference Manual Revision C...
Page 115
Smart DC Controller Troubleshooting Revision C Reference 6-17...
Page 116
Smart DC Controller Troubleshooting 6-18 SlideSmart Installation and Reference Manual Revision C...
Page 117
Smart DC Controller Troubleshooting Revision C Reference 6-19...
Page 118
Smart DC Controller Troubleshooting 6-20 SlideSmart Installation and Reference Manual Revision C...
Page 119
Smart DC Controller Troubleshooting Revision C Reference 6-21...
Page 120
Smart DC Controller Troubleshooting 6-22 SlideSmart Installation and Reference Manual Revision C...
Page 121
Smart DC Controller Troubleshooting Alert or Error LCD Description Advisory Resolution Revision C Reference 6-23...
Page 122
Smart DC Controller Troubleshooting Installer Setting Options Menu LCD Description Bold = Factory Settings 0 = Run mode 0 = Run mode 0 = Run mode 0 = Run mode 6-24 SlideSmart Installation and Reference Manual Revision C...
Page 123
Smart DC Controller Troubleshooting Revision C Reference 6-25...
Page 124
Smart DC Controller Troubleshooting 6-26 SlideSmart Installation and Reference Manual Revision C...
Page 125
General Maintenance RS-232 Connect to RS-232 with a HySecurity adapter. If using a USB cable, connect it to the USB port. USB PORT RS-485 COMMUNICATION Technical Support S.T.A.R.T. software for Smart Touch and Smart DC I accept Revision C Reference...
Page 126
General Maintenance Installing START Software, continued Setting User Account Controls In Windows 7: In Vista: Table 6-1 "Smart DC Controller - Troubleshooting" on page 6-17 6-28 SlideSmart Installation and Reference Manual Revision C...
The software on the SDC board is constantly being enhanced with new features that create an easier install and improve the on board diagnostic tools. Be sure to check the HySecurity website for the latest version of software before heading out for field maintenance.
General Maintenance Slide the motor bracket. 1/16" to 1/8" To adjust the tension or replace the belt, loosen 4 nuts and slide the motor bracket. Retighten the fasteners when the adjustments are complete. 6-30 SlideSmart Installation and Reference Manual Revision C...
Page 129
General Maintenance Setting AC Power Loss Gate Function Disconnect wires Cut away view of chassis Access window Revision C Reference 6-31...
Page 130
General Maintenance Slide cover Four Phillips-head off the screws secure the wire ties control box control box to the to access chassis. the screws. battery Battery access window Control box 6-32 SlideSmart Installation and Reference Manual Revision C...
Page 131
General Maintenance Lithium ba ery Revision C Reference 6-33...
Page 132
General Maintenance This page intentionally blank. 6-34 SlideSmart Installation and Reference Manual Revision C...
Page 134
3.25 2.50 Chain to Gate Gate 5.50 2.66 Chain, #40 Roller 10.50 Conduit 21.0 Min. pad size Area 7 x 12 1.63 Provisions for qty 4 ½ - 13 X 3 ½ Concrete Anchors (½-inch slot in either direction) ( 4.31 ) 10.38 19.0 Min.
Page 135
Gate 3.25 2.50 Chain Chain to Gate 20.0 Route 6 AWG ground wire through conduit & attach to ground lug provided. 17.7 20.7 Earth Ground High Voltage Master/Slave Wires (Optional) Vehicle Loop Consult local Control Wires codes for proper depth Low Voltage / Communication Wires 3 Foot...
Page 136
SLIDESMART DC: BASE RISER MOUNTED 3.25 2.50 Chain Gate Chain to Gate 5.50 2.66 10.50 12.00 17.50 Conduit Area 7 x 7 Conduit Area If no batteries in Base Riser - Conduit Area is 7 x 12 inches. ½ - 13 X 3 ½ Concrete Anchors (4x) 10.38 18.00...
Page 137
Gate Chain Chain to Gate 3.35 2.66 8.35 10.50 U-bolts provided for 4” OD pipe (slot allows for 3.5" - 4.5" OD pipe). For best results, HySecurity recommends welding plate to posts. 5.00 4.00 .656 5.50 3.81 10.38 18.0 3.25 2.50...
Page 138
Chain Chain to Gate 3.35 2.66 8.35 10.50 U-bolts provided for 4” OD pipe (slot allows for 3.5" - 4.5" OD pipe). For best results, HySecurity recommends welding plate to posts. 5.00 4.00 .656 3.25 5.50 2.50 Chain to Gate 3.81...
Page 139
SLIDESMART DC: REAR MOUNTED INSTALLATION DETAIL B 4.75 7.75 3.25 NOTE: DRAWING IS NOT TO SCALE. DIMENSIONS SHOWN IN INCHES UNLESS STATED OTHERWISE. DOCUMENT TITLE DRAWN DATE DOCUMENT NUMBER: 11/10/09 D0335 SLIDESMART INSTALLATION CHECKED DATE SPECIFICATION APPROVED DATE THIRD ANGLE PROJECTION 11/10/09 Kent, Washington Revision C...
Page 140
SlideSmart Installation and Reference Manual Revision C...
Page 141
Board, Smart DC Controller Control Box Buzzer Reset Switch, Internal Switch, On/Off Detector, Vehicle Circuit Breaker Switch, On/Off Board, Power Supply Cover, 2-Piece Belt, Drive Pulley, Motor Pulley, Gearbox Gearbox Motor, Electric Transformer Brush Kit Solar Control Box Sprocket Target, Magnet Chain Idler Wheel Battery Kit, 8 Ah...
Page 142
Part Name Part Number SlideSmart Models Base Extension MX002094 Battery Kit, 50AH, Replacement MX002013 Battery Kit, 8AH, Replacement MX002008 Belt, Drive, SlideSmart DC 10F MX002107 SlideSmart 10F Belt, Drive, SlideSmart DC 15 MX002106 SlideSmart 15 Board, Power Supply, 115/230VAC MX001766 AC only Board, Smart DC Controller MX001457...
Page 143
Warranty. Exclusion of Other Warranties. 1a. Five Year / Seven Year Warranty Items (Registered Gate Operators Purchased from Authorized Distributors) Buyer's Exclusive Remedies for Any Nonconformity. 1b. One Year Warranty Items (Operators Not Purchased from an Authorized Distributor or Registered within 60 Days) Exclusion of Consequential and Incidental Damages.
Page 144
Additionally, HySecurity Gate Inc. makes no representations or warranty with respect to this manual. We also reserve the right to make changes in the products described without notice and without any obligation to notify any persons of any such revision or change.