Emergency Fast Close; Installing A Push Button Device For Emergency Fast Operate (Efo) - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

e
f
MerGenCy
The Emergency Fast Close setting in combination with a constant hold to close, overrides vehicle detectors,
photo eyes and edge sensors and closes the barrier arm. To enable the Emergency Fast close option:
NOTE: When you are in programming mode the buttons on the keypad change from Open, Close, and
Stop to Previous, Next, and Select. Refer to Menu Mode Navigation on page 60.
1. Make sure the operator is turned ON and a Run mode status (ex., GATE OPEN)
appears on the Smart Touch Controller, which indicates the machine
is operational.
2. Press the Menu button twice to access the User Menu.
3. Press and hold the Reset button and then the Open button. Hold the buttons for
two seconds and then release both buttons. FO x appears on the display which
indicates you have accessed the Installer Menu.
4. Press Next until the Emergency Close OC 0
5. Press Select and OC starts blinking, which indicates the display can be changed.
6. Press Next or Previous to change the display to OC 1.
7. Press Select to accept the entry. (The display characters stop linking.)
8. Press Program to exit programming mode and return to Run mode.
A Run mode gate status appears (ex., GATE OPEN).
i
nstallinG a
o
(efo)
Perate
The Emergency Fast Close on the 50VF-series is designed for
a constant hold function, such as a push-button device that is held
for the duration of gate travel. To operate properly, the device
must be connected to Terminal 23 on the Smart Touch Controller
and a +24VDC terminal on the Power Supply Board.
When the connections are made, the constant hold signal
transmitted to the Smart Touch Controller activates the close
function. The gate closes at a higher speed than usual. Photo
eyes, vehicle loop inputs, and other safety devices (such as
external entrapment protection sensors) are ignored.
MX3657-01 Rev. D ©2020
C
ast
lose
P
B
ush
utton
Initial Setup
appears on the display.
d
e
eViCe for
Power Supply Board
hysecurity.com | 800-321-9947
HYSECURITY
GATE OPEN
OC 1
EMERGENCY CLOSE
f
MerGenCy
ast
Power Connector
DRIVE
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
10
VEHICLE DETECTOR
Emergency Fast
OUTSIDE OBSTRUCTION
11
Close Device
VEHICLE DETECTOR
(Actuator)
12
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
14
SENSOR COM
15
SENSOR COM
16
DO NOT USE
17
SENSOR 2
18
DO NOT USE
19
SENSOR 3
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RPM
COM
A
POWER
RS485
COM
NO
STATUS
HySecurity
MX000585
VERSION
S/N
RADIO OPTIONS
S1
B
COM
OPEN
+24V
+24V
COM
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents