HySecurity StrongArm 14F Programming And Operations Manual page 82

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

Setting
7
Gate forced open output
8
Gate open too long output
9
Safety Mode Alert output
10
Entrapment Mode Alert output
11
Unauthorized Vehicle Entry output
(Tail gate alert)
12
Outside Obstruction Vehicle
Detector output
13
Loitering Alert
14
Gate nearing full travel output
15
Gate failure output
16
Motor Running output
17
AC Power Failure output
18
DC Power Failure output
82
hysecurity.com | 800-321-9947
Performance
Activated if the gate is forced off the closed limit switch and
the operator is not able to restore the gate to full closed
position within four seconds.
NOTE: This alarm resets itself in 30 seconds.
Controls an external device. Activates when the gate is open
longer than the user-selected period of time. Adjustable
from 0 seconds with 15 to 135s selectable delay timeframes
in 30s increments.
NOTE: TL - Open TIME ALERT adjustments can be made
in the Installer Menu. The TL Installer Menu display only
appears when using this relay.
Controls an external device. Activated when the system is
in Safety Mode or Entrapment Mode. Safety Mode occurs
when the gate encounters an obstruction. Entrapment
Mode means the gate is stopped. Entrapment mode occurs
if the inherent entrapment sensor triggers while the system is
in Safety Mode.
Controls an external device. Activated only when in the
Entrapment Mode.
Controls an external device. Activated when a second vehicle
enters from the outside without a valid input from an access
control device. This output releases when an access control
input signals open or the arm/gate reaches the close limit.
Interlocks an entry device to prevent pedestrian use. This
output is active whenever the Outside Obstruction Loop
Detector is tripped.
Indicates a vehicle is loitering on the Outside Obstruction
Loop. Adjustable from 0 seconds with 15 to 135s selectable
delay timeframes in 30s increments.
NOTE: LT LOITERING ALERT adjustments can be made
in the Installer Menu. The LT Installer Menu display only
appears when using this relay.
Applies to operators with position sensors only. Activated
when the gate is 3s from expected limit switch trigger.
NOTE: If the operator has not yet learned limits, it will
energize Relay 14 when the motor begins moving the gate.
Activated to report occurrence of a problem. Indicates
the system is in an Error Mode, Fault Mode or Entrapment
Mode.
Active when the motor is running and gate is in motion.
This relay is normally energized and drops with loss of AC
power.
DC operators only. The relay activates when the battery
power is very low, but the output ceases when the battery is
dead. The relay is triggered when the battery is less than 20
volts.
Description
StrongArm Programming and Operations
Wire
Connection
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
Relay 1, 2 or 3
MX3657-01 Rev. D ©2020