Defining machine axis AX4 as linear axis and equidistant indexing axis
MD30300 $MA_IS_ROT_AX[ AX4 ] = 1
MD30310 $MA_ ROT_IS_MODULO[ AX4 ] = 1
MD30500 $MA_INDEX_AX_ASSIGN_POS_TAB[ AX4 ] = 3
MD36100 $MA_POS_LIMIT_MINUS[ AX4 ] = -200.0
MD36110 $MA_POS_LIMIT_PLUS[ AX4 ] = 200.0
16.8
Data lists
16.8.1
Machine data
16.8.1.1
General machine data
Number
Identifier: $MN_
10260
CONVERT_SCALING_SYSTEM
10270
POS_TAB_SCALING_SYSTEM
10900
INDEX_AX_LENGTH_POS_TAB_1
10910
INDEX_AX_POS_TAB_1[n]
10920
INDEX_AX_LENGTH_POS_TAB_2
10930
INDEX_AX_POS_TAB_2[n]
10940
INDEX_AX_MODE
16.8.1.2
Axis/spindlespecific machine data
Number
Identifier: $MA_
30300
IS_ROT_AX
30310
ROT_IS_MODULO
30320
DISPLAY_IS_MODULO
30500
INDEX_AX_ASSIGN_POS_TAB
30501
INDEX_AX_NUMERATOR
30502
INDEX_AX_DENOMINATOR
30503
INDEX_AX_OFFSET
30505
HIRTH_IS_ACTIVE
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Rotary axis
Modulo function active
Equidistant indexing axis
1. Software limit switch minus = -200.0
mm
1. Software limit switch plus = 200.0 mm
Description
Basic system switchover active
System of measurement of position tables
Number of positions for indexing axis table 1
Indexing position table 1
Number of positions for indexing axis table 2
Indexing position table 2
Options for indexing positions
Description
Rotary axis
Modulo conversion for rotary axis
Position display is modulo 360°
Axis is indexing axis
Numerator for indexing axes with equidistant positions
Denominator for indexing axes with equidistant posi‐
tions
Indexing position for indexing axes with equidistant po‐
sitions
Hirth tooth system is active
T1: Indexing axes
16.8 Data lists
835