Siemens SINUMERIK 840D sl Function Manual page 96

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

B3: Distributed systems - 840D sl only
3.2 NCU link
Figure 3-8
Note
Memory structure
The data in the link variables memory is always arranged randomly and may therefore appear
different (although the data format limits will still be taken into account).
Access via a link variable must be programmed as follows, in accordance with the memory
structure defined:
Program code
$A_DLB[0]
$A_DLB[1]
$A_DLW[2]
$A_DLD[4]
$A_DLD[8]
$A_DLD[12]
$A_DLR[16]
96
Example: Structure of the link variables memory
Description
;
BYTE(1)
;
BYTE(2)
;
WORD
;
DWORD(1)
;
DWORD(2)
;
DWORD(3)
;
REAL
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Extended Functions