Measurement Of An Oblique Angle In A Plane (Measurement Type 17) - Siemens SINUMERIK 840D sl Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

M5: Measurement
8.5 Setting zeros, workpiece measuring and tool measuring
Input variable
$AC_MEAS_INPUT[0]
$AC_MEAS_INPUT[1]
$AC_MEAS_TYPE
* optional
The following output variables are written for measurement type 16:
Output variable
$AC_MEAS_FRAME
$AC_MEAS_WP_ANGLE
8.5.3.9

Measurement of an oblique angle in a plane (measurement type 17)

Measurement of an angle in an inclined plane ($AC_MEAS_TYPE = 17)
The oblique plane is determined using three measuring points P1, P2 and P3.
Figure 8-13
540
Meaning
Unless otherwise specified, the reference coordinate for the align‐
ment of the workpiece is always the abscissa of the selected
plane. *
=0: Reference coordinate is the abscissa
=1: Reference coordinate is the ordinate
Unless otherwise specified, the workpiece position angle is en‐
tered in the frame as a rotation. Otherwise, a channel axis index
can be specified for a rotary axis whose translation is set to the
current rotary axis position plus the calculated rotation. The work‐
piece is then aligned at rotary axis position = 0. The current rotary
axis value must be set in $AA_MEAS_POINT[axis]. *
16
Oblique plane in G17
Meaning
Result frame with rotation
Calculated workpiece position angle
Function Manual, 10/2015, 6FC5397-1BP40-5BA3