Functional Test And Repeat Accuracy - Siemens SINUMERIK 840D sl Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

M5: Measurement
8.8 Channels - only 840D sl
Continuous measurement with deletion of distance-to-go
Delete distance-to-go after last measurement.
Program code
N1
N2
N3
N4
N5
N6
N7
N8
N9
Continuous modal measurement over several blocks
Program code
N1
N2
N3
N4
N5
N6
N7
N8
N9
N10
N11
8.8.4

Functional test and repeat accuracy

Function test
Program code
%_N_PRUEF_MESSTASTER_MPF
;$PATH=/_N_MPF_DIR
;Testing program probe connection
N05 DEF INT MTSIGNAL
N10 DEF INT ME_NR=1
584
DEF INT ANZAHL=100
DEF REAL MESSWERT[ANZAHL]
DEF INT INDEX=0
WHEN $AC_FIFO1[4]==ANZAHL DO DELDTG (X) MEAC[X] =(0)
MEAC[X]=(1, 1, -1) G01 X1000 F100
R1=$AC_FIFO1[4]
FOR INDEX=0 TO R1
MESSWERT[INDEX]=$AC_FIFO1[0]
ENDFOR:
DEF INT ANZAHL=100
DEF REAL MESSWERT[ANZAHL]
DEF INT INDEX=0
ID=1 MEAC[X]=(1, 1, -1)
ID=2 WHEN $AC_FIFO1[4]==ANZAHL DO MEAC[X]=(0) CAN-
CEL(2)
G01 X1000 Y100
X100 Y100
R1=$AC_FIFO1[4]
FOR INDEX=0 TO R1
MESSWERT[INDEX]=$AC_FIFO1[0]
ENDFOR:
Comment
;Flag for trigger status
; measurement input number
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Comment
; Start measurement
;Number of measured
values
; Read out measured
values
Comment
; Start measurement
;Number of measured
values
; Read out measured
values
Extended Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents