Z2: NC/PLC interface signals
19.1 Digital and analog NCK I/Os (A4)
DB10
DBB168
Disable analog NCK outputs
Signal state 0 or edge
The analog output of the NCK is enabled. As a result, the value set by the NC part program or the
change 1 → 0
PLC is output at the hardware output.
Corresponding to ....
DB10 DBB166 (Overwrite screen form of analog NCK outputs)
DB10 DBB167 (Setting screen form of analog NCK outputs)
DB10 DBB170-185 (Setting by PLC of analog NCK outputs)
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
DB10
DBB170 - 185
Setting value from PLC for analog NCK outputs
Edge evaluation: No
Signal state 1 or edge
With this setting value, the value for the analog hardware output can be changed by the PLC. There
change 0 → 1
are two possibilities:
● With the "Overwrite screen form":
● With the "setting screen form":
The setting value from the PLC is specified as a fixed point number (16 bit value including sign) in
2's complement.
Signal state 0 or edge
As the interface signal is only evaluated by the NCK on signal transition 0 → 1 it must be reset to "0"
change 1 → 0
again by the PLC user program in the next PLC cycle.
Special cases,
Note:
errors, ....
The PLC interface for the setting value is used both by the overwrite screen form (for signal transition
0 → 1) and the setting screen form (for signal state 1). Simultaneous activation of the two screen
forms must be avoided via the PLC user program.
Corresponding to ....
DB10 DBB168 (Disable analog NCK outputs)
DB10 DBB166 (Overwrite screen form of analog NCK outputs)
DB10 DBB167 (Setting screen form of analog NCK outputs)
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
19.1.2

Signals from NC (DB10)

Overview of signals from NC to PLC
DB10
DBB
60
64
882
Signal(s) updated: Cyclic
With signal transition 0 → 1 in the 'overwrite screen form' the PLC overwrites the previous 'NCK
value' with the 'setting value'. This is the new "NCK value".
On signal state 1 in the "setting screen form", the "PLC value" is activated. The value used is the
'setting value'.
Signals from NC interface NC → PLC
Bit 7
Bit 6
Actual value for digital NCK inputs
Setpoint for digital NCK outputs
Digital inputs without hardware *)
Bit 5
Bit 4
Bit 3
(on-board inputs) **)
Input 4
on-board outputs **)
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Bit 2
Bit 1
Bit 0
Input 3
Input 2
Input 1
Extended Functions