Siemens SINUMERIK 840D sl Function Manual page 548

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

M5: Measurement
8.5 Setting zeros, workpiece measuring and tool measuring
The following output variables are written for measurement type 19:
Output variable
$AC_MEAS_FRAME
Example
1-dimensional setpoint selection
Program code
DEF INT RETVAL
DEF REAL _CORMW_XX,
_CORMW_YY,
_CORMW_ZZ
DEF AXIS _XX, _YY, _ZZ
T1 D1
G54
$AC_MEAS_VALID = 0
$AC_MEAS_TYPE = 19
$AC_MEAS_ACT_PLANE = 0
_XX=$P_AXN1
_YY=$P_AXN2
_ZZ=$P_AXN3
$AA_MEAS_POINT1[_xx] = $AA_MW[_xx]
$AA_MEAS_POINT1[_yy] = $AA_MW[_yy]
$AA_MEAS_POINT1[_zz] = $AA_MW[_zz]
$AA_MEAS_SETPOINT[_xx] = 10
$AC_MEAS_FRAME_SELECT = 102
RETVAL = MEASURE()
if RETVAL <> 0
setal(61000 + RETVAL)
endif
$P_UIFR[2] = $AC_MEAS_FRAME
G55 G0 AX[_xx]=10 AX[_yy]=10
m30
2-dimensional setpoint value ($AC_MEAS_TYPE = 20)
Setpoints for two dimensions can be defined using this measuring method. Any combination
of 2 out of 3 axes is permissible. If three setpoints are specified, only the values for the abscissa
and the ordinate are accepted. The tool is not taken into account.
This is a purely actual value memory preset.
548
Meaning
Result frame with rotations and translation
Comment
; Activate probe
; Activate all frames and G54
; Set all input values to invalid
; Set measurement type for 1-dimensional
setpoint selection
; Measuring plane is G17
; Define axes according to the plane
; Assign measured values
; Assign measurement value to abscissa
; Assign measurement value to ordinate
; Assign measurement value to applicate
; Define setpoint for abscissa
; Select target frame - G55
; Start measurement calculation
; Write measurement frame in data management
(G55)
; Activate frame and traverse
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Extended Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d