15.4.2
Commissioning
You can adjust the default memory division by increasing/decreasing individual memory areas
for each user.
Basic procedure:
1. Load standard machine data.
References:
Commissioning the CNC: NC, PLC, Drive; section "Requirements for commissioning" >
"Power-on and startup"
2. Determining the maximum possible size of the static user memory (including the optional
memory expansion):
MD18230 $MN_MM_USER_MEM_BUFFERED
3. Optional: modifying the size of the static user memory:
– MD19250 $ON_USER_MEM_BUFFERED
– Perform a power-on reset.
4. Optional: setting the size partitions U and M:
– MD18352 $MN_MM_U_FILE_MEM_SIZE
– MD18353 $MN_MM_M_FILE_MEM_SIZE
5. Optional: setting up additional channels of the control:
MD10010 $MC_ASSIGN_CHAN_TO_MODE_GROUP
6. Optional: setting the size of the memory areas of the active file system (tool management,
global user data, ...):
– Determining the free static user memory:
– Setting the size of the memory areas of the active file system in the machine data that
7. Perform a power-on reset.
The memory will be reconfigured the next time the control starts up.
References:
For a detailed description of machine data, refer to:
● List Manual Machine Data and Parameters
15.5
Configuration of the dynamic user memory
15.5.1
Division of the dynamic NC memory
The dynamic NC memory is used jointly by the system and by the user. The area available to
the user is defined as the dynamic user memory.
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
MD18060 $MN_INFO_FREE_MEM_STATIC
configure memory (...MM_...).
S7: Memory configuration
15.5 Configuration of the dynamic user memory
805