Siemens SINUMERIK 840D sl Function Manual page 541

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

$AC_MEAS_TYPE = 17 defines two resulting angles α
are entered in $AC_MEAS_RESULTS[0..1]:
● $AC_MEAS_RESULTS[0] → Rotation at the abscissa
● $AC_MEAS_RESULTS[1] → Rotation at the ordinate
These angles are calculated by means of the three measuring points P1, P2 and P3. In this
type of measurement the angle for the applicate ($AC_MEAS_RESULTS[2]) is always pre-
filled with 0.
A setpoint rotation that is entered in the result frame can be input for the abscissa and/or the
ordinate. If only one angle is specified with a setpoint, the second angle is calculated such that
the three measuring points are on an oblique plane with the setpoint angle. Only rotations are
entered in the result frame, the WCS reference point is retained. The WCS is rotated such that
z' is perpendicular to the oblique plane.
The following plane settings are defined for measurement type 17:
Axis identifier
Abscissa
Ordinate
Applicate (infeed axis)
The values of the following variables are evaluated for measurement type 17:
Input variable
$AC_MEAS_VALID
$AA_MEAS_POINT1[axis]
$AA_MEAS_POINT2[axis]
$AA_MEAS_POINT3[axis]
$AA_MEAS_SETANGLE[axis]
$AC_MEAS_ACT_PLANE
$AC_MEAS_FRAME_SELECT
$AC_MEAS_T_NUMBER
$AC_MEAS_D_NUMBER
$AC_MEAS_INPUT[0]
$AC_MEAS_TYPE
* optional
The following output variables are written for measurement type 17:
Output variable
$AC_MEAS_FRAME
$AC_MEAS_RESULTS[0]
$AC_MEAS_RESULTS[1]
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
8.5 Setting zeros, workpiece measuring and tool measuring
and α
0
G17
G18
x axis
z axis
y axis
x axis
z axis
y axis
Meaning
Validity bits for input variables
Measuring point 1
Measuring point 2
Measuring point 3
Setpoint rotations around abscissa and ordinate *
Calculated as active plane unless otherwise specified *
Calculated as additive frame unless otherwise specified *
Calculated as active T unless otherwise specified (T0) *
Calculated as active D unless otherwise specified (D0) *
Unless otherwise specified,
the points are not projected in a plane *
0: Points are not projected on a plane
1: Points are projected in the active plane or in the selected plane
17
Meaning
Result frame
Angles around abscissa from which three measuring points are
calculated
Angles around ordinate from which three measuring points are
calculated
M5: Measurement
for the skew of the plane; these
1
G19
y axis
z axis
x axis
541