P5: Oscillation
12.6 Data lists
$AC_TIMES
$AC_TIMEC
$AC_TIMESC
$AC_DTBB
$AC_DTBW
$AA_DTBB[<axial expression>]
$AA_DTBW[<axial expression>]
$AC_DTEB
$AC_DTEW
$AA_DTEB[<axial expression>]
$AA_DTEW[<axial expression>]
$AC_PLTBB
$AC_PLTEB
$AC_VACTB
$AC_VACTW
$AA_VACTB[<axial expression>]
$AA_VACTW[<axial expression>]
$AA_DTEPB[<axial expression>]
$AA_DTEPW[<axial expression>]
$AC_DTEPB
$AC_DTEPW
$AC_PATHN
728
Time from the start of the block (real) in seconds
(without times for the internally generated intermedi‐
ate blocks)
Time from the start of the block (real) in IPO steps
(including steps for the internally generated inter‐
mediate blocks)
Time from the start of the block (real) in IPO steps
(without steps for the internally generated intermedi‐
ate blocks)
Distance from beginning of block in BCS
(Distance to begin, baseCoor) (real)
Distance from beginning of block in PCS
(Distance to begin, workpieceCoor) (real)
axial distance from beginning of block in BCS
(Distance to begin, baseCoor) (real)
axial distance from beginning of block in PCS
(Distance to begin, workpieceCoor) (real)
Distance to end of block in BCS (Distance to end)
(Distance to end, baseCoor) (real)
Distance to end of block in PCS
(Distance to end, workpieceCoor) (real)
axial distance to end of movement in BCS
(Distance to end, baseCoor) (real)
axial distance to end of movement in PCS
(Distance to end, workpieceCoor) (real)
Distance from beginning of block in BCS
(Path Length from begin, baseCoor) (real)
Distance to end of block in BCS (Distance to end)
(Path Length to end, baseCoor) (real)
Path speed in BCS
(Velocity actual, baseCoor) (real)
Path speed in PCS
(Velocity actual, workPieceCoor) (real)
Axis velocity in BCS
(Velocity actual, baseCoor) (real)
Axis velocity in PCS
(Velocity actual, workPieceCoor) (real)
axial distance-to-go for oscillation infeed in BCS
(Distance to end, pendulum, baseCoor) (real)
axial distance-to-go for oscillation infeed in PCS
(Distance to end, pendulum, workpieceCoor) (real)
Path distance-to-go for oscillation infeed in BCS
(not P2) (Distance to end, pendulum, baseCoor) (re‐
al)
Path distance-to-go for oscillation infeed in PCS
(not P2) (Distance to end, pendulum, workpiece‐
Coor) (real)
(Path parameter normalized) (real)
Normalized path parameter: 0 for beginning of block
to 1 for end of block