DB10
DBX107.6
Signal irrelevant for ...
References
19.2.4
Signals from axis/spindle (DB31, ...)
DB31, ...
DBX60.1
Edge evaluation:
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Signal irrelevant for ...
Additional references
DB31, ...
DBX61.2
Edge evaluation:
Meaning
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
DB31, ...
DBX62.7
Edge evaluation:
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
NCU link active
System with an NCU.
Device Manual, NCU 7x0.3 PN
NCU link axis active
Signal(s) updated:
Axis is active as NCU link axis.
Axis is used as a local axis.
System with an NCU.
NCU 7x0.3 PN Manual
Axis ready
Signal(s) updated:
The signal is routed on the NCU in the NCU link group to which the axis is physically connected.
Axis is ready.
Axis is not ready.
This status will be set when the channel, the operating modes group or the NCK have generated
the alarm "not ready".
Axis container rotation active
Signal(s) updated:
An axis container rotation is active for the axis.
An axis container rotation is not active for the axis.
Z2: NC/PLC interface signals
19.2 Distributed systems (B3)
895