N4: Own channel - only 840D sl
10.3 Activation and deactivation
10.2.7
Signal monitoring
Oscillating signal
Owing to aging of the punch hydraulics, overshooting of the punch may cause the "Stroke
active" signal to oscillate at the end of a stroke.
In this case, an alarm (22054 "undefined punching signal") can be generated as a function of
machine data:
MD26020 $MC_NIBBLE_SIGNAL_CHECK
.
Reset response
In the case of an NCK reset, the interface signal:
DB21, ... DBX38.0 (stroke initiation active)
is canceled immediately without acknowledgement by the high-speed input.
A currently activated stroke cannot be suppressed.
10.3
Activation and deactivation
10.3.1
Language commands
Punching and nibbling functions are activated and deactivated via configurable language
commands. These replace the special M functions that were used in earlier systems.
References:
Programming Manual, Job Planning
Groups
The language commands are subdivided into the following groups:
Group 35
The actual punching and nibbling-specific functions are activated and deactivated by means of the
following language commands:
PON
SON
PONS
SONS
SPOF
618
= punching ON
= nibbling ON
= punching ON, activated in the position controller
= nibbling ON, activated in the position controller
= punching/nibbling OFF
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
Extended Functions