Measurement Of A Groove (Measurement Type 12) - Siemens SINUMERIK 840D sl Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Input variable
$AC_MEAS_FINE_TRANS
$AC_MEAS_FRAME_SELECT
$AC_MEAS_T_NUMBER
$AC_MEAS_D_NUMBER
$AC_MEAS_TYPE
* optional
The following output variables are written for measurement type 9:
Output variable
$AC_MEAS_FRAME
$AC_MEAS_DIAMETER
$AC_MEAS_RESULTS[0]
$AC_MEAS_RESULTS[1]
$AC_MEAS_RESULTS[2]
$AC_MEAS_RESULTS[3]
8.5.3.5

Measurement of a groove (measurement type 12)

Measuring points for determining the position of a groove ($AC_MEAS_TYPE = 12)
A groove is measured by approaching the two outside corners or inner edges. The groove
center can be set to a setpoint position. The component of the approach direction determines
the groove position.
Figure 8-8
The values of the following variables are evaluated for measurement type 12:
Input variable
$AC_MEAS_VALID
$AA_MEAS_POINT1[axis]
$AA_MEAS_POINT2[axis]
$AA_MEAS_SETPOINT[axis]
$AC_MEAS_DIR_APPROACH
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
8.5 Setting zeros, workpiece measuring and tool measuring
Groove
Meaning
0: Coarse offset, 1: Fine offset *
Calculated as additive frame unless otherwise specified *
Calculated as active T unless otherwise specified (T0) *
Calculated as active D unless otherwise specified (D0) *
9
Meaning
Result frame with translation
Diameter of hole
Abscissa of the calculated center point
Ordinate of the calculated center point
Applicate of the calculated center point
Quality of the circle adjustment: Sum of the distance
squares
Meaning
Validity bits for input variables
Measuring point 1
Measuring point 2
Setpoint position of groove center *
0: +x, 1: -x, 2: +y, 3: -y, 4: +z, 5: -z
M5: Measurement
533