Commissioning

10.4 Series commissioning

Step 8:
Carry out the acceptance test and enter in the logbook.
● All of the safety functions that have been enabled must be tested. For suggestions on how
to test and check activated SI functions, please refer to Chapter "User agreement
(Page 92)".
● The parameterization of all PROFIsafe I/O components should be checked using a function
test and checking the printout of the hardware configuration from SIMATIC Step 7.
Step 9:
● Save all machine data using the "Services" area. This data can be used to commission
series equipment.
● Save (back-up) the complete SIMATIC Step7 project.
Old MD files
After the acceptance test has been completed, all illegal (old) MD files must be removed from
the Flashcard (to avoid confusion between old and new data). Data that corresponds to the
acceptance test data must be backed-up (archived).
Step 10:
Delete (clear) the password in order to prevent the unauthorized change of machine data.
See also
Acceptance test (Page 543)
10.4
Series commissioning
The setting for the safety monitoring functions is automatically transferred with other data in
the course of a normal series commissioning process. The following steps need to be taken
in addition to the normal commissioning procedure:
1. Enter a user agreement
2. Carry out the acceptance test
Sequence of operations for series commissioning
The following sequence of operations is recommended when commissioning series equipment:
● Download the data set for the series machine into the control.
● Adjust the absolute encoder.