F30651
SI P2: Synchronization with the Control Unit unsuccessful
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Explanation
The "Safety Integrated" function integrated in the drive requires that the safety time slices are synchronized
in both monitoring channels. This synchronization routine was not successful.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy
Carry out a POWER ON (power off/on) for all components
Upgrade the Motor Module/Hydraulic Module software.
Upgrade the Control Unit software.
F30652
SI P2: Monitoring clock cycle not permissible
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Explanation
The Safety Integrated monitoring clock cycle cannot be maintained due to the communication conditions
requested in the system.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy
When fault F01652 simultaneously occurs, apply the remedy/countermeasure described there.
Upgrade the firmware of the Motor Module/Hydraulic Module to a later version.
F30655
SI P2: Aligning the monitoring functions
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
11.3 Safety messages for SINAMICS S120
Diagnostics
741