Diagnostics
11.3 Safety messages for SINAMICS S120
F30655
SI P2: Aligning the monitoring functions
Explanation
An error has occurred when aligning the Safety Integrated monitoring functions for the two monitoring chan‐
nels. A common set of supported SI monitoring functions was not able to be determined.
● DRIVE-CLiQ communications has an error or failed.
● Safety Integrated software releases on the Control Unit and the Motor Module/Hydraulic Module are not
compatible with one another.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret as hexadecimal):
Only for internal Siemens troubleshooting.
Remedy
Carry out a POWER ON (power off/on) for all components
Upgrade the Motor Module/Hydraulic Module software.
Upgrade the Control Unit software.
Check the electrical cabinet design and cable routing for EMC compliance.
F30656
SI P2: Incorrect Motor Module parameter
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Explanation
When accessing the Safety Integrated parameters for monitoring channel 2 in the non-volatile memory, an
error has occurred.
Note:
This fault results in a STOP A that can be acknowledged.
Fault value (r0949, interpret decimal):
129: Safety parameters for monitoring channel 2 corrupted. Drive with enabled safety functions possibly
copied offline using the commissioning software and the project downloaded.
131: Internal software error on the Control Unit.
255: Internal Motor Module/Hydraulic Module software error.
Remedy
Recommission the safety functions.
Upgrade the Control Unit software.
Upgrade the Motor Module/Hydraulic Module software.
Replace the memory card or the Control Unit.
● For fault value = 129:
Activate the safety commissioning mode (p0010 = 95).
Adapt the PROFIsafe address (p9610).
Start the copy function for SI parameters (p9700 = D0 hex).
Acknowledge data change (p9701 = DC hex).
Exit the safety commissioning mode (p0010 = 0).
Save all parameters (p0977 = 1 or "Copy RAM to ROM").
Carry out a POWER ON (power off/on) for all components.
F30659
SI P2: Write task for parameter rejected
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
742
Function Manual, 12/2017, 6FC5397-4BP40-6BA1