Siemens SINUMERIK 840D sl Function Manual page 549

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measure
Documentation
SW upgrade
Supplementary
3
software version
(NCU/drive/PLC)
Software upgrade
Supplementary
(HMI)
software version
Changing an indi‐
Inclusion of SI
vidual limit value
function per axis
(e.g. SG limit)
Expanded function
Inclusion of the SI
(e.g. additional ac‐
function per axis,
tuator, additional
function table
SG stage)
SPL change
Inclusion of the SI
function per axis,
function table
Data transferred to
Possibly supple‐
additional ma‐
ment, machine de‐
chines with series
scription (check
commissioning
the SW version)
Regarding the acceptance test, the notes in the documentation of the SW upgrade must be carefully observed.
1
An update involves an update to a new Service Pack (SP) or a new Hotfix (HF) within a software line, e.g. 02.05.01.03 (01
2
= Service Pack; 03 = Hotfix) to 02.05.02.03 (does not take into account any change of the Safety functionality).
An upgrade involves an upgrade to a new software release, e.g. 02.05.xx.xx to 02.06.xx.xx or 02.xx.xx.xx. to 03.xx.xx.xx
3
(does not take into account any change of the Safety functionality).
If no checksums have changed, then a complete function test, Part 2 does not have to be performed. However, a test
4
should be performed with reduced test scope.
Test with reduced test scope
Test of the Safety Integrated Functions at any axis (each NCU and each NX) and a comparison with the test results before
the upgrade.
Note:
If the results of function test, Part 2 are taken from another identical machine, then this is the sole responsibility of the machine
manufacturer and should be appropriately commented in the acceptance report.
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Function test
Function test
Part 1
No
No
1
1, 4
No
No
No
Yes, only test the
corresponding
functions at the ax‐
es involved
Yes, only for the
Yes, only for the
tests influenced by
tests influenced by
the function expan‐
the function expan‐
sion
sion
Yes, only Point 2.6 No
Yes
No
Supplementary
measures
Part 2
Points 4.3 and 4.4
No
No
No
No
Points 4.1 and 4.5
Commissioning
10.6 Acceptance test
Completion of the
report
Document
changed check‐
sum
No
Document
changed check‐
sum
Document
changed check‐
sum
Document
changed check‐
sum
Document
changed check‐
sum
549