27072
Checksum error, enabling safe communication. Confirmation and acceptance test required!
Parameter
Explanation
The NCK-MD to enable the SPL coupling (also including MD13302/13303 $MN_PROFISAFE_IN/OUT_EN‐
ABLE_MASK, MD13330/13340 $MN_SAFE_RDP/SDP_ENABLE_MASK) are protected by a checksum. The
alarm indicates that the actual checksum no longer matches the saved checksum, i.e. that either a piece of
data was illegally changed or is corrupt.
Response
Alarm display
Interface signals are set
NC start disable in this channel
NC stop for alarm
Mode group not ready
Channel not ready
Remedy
Check the machine data, recalculate the checksum and correct. Re-accept the safety functions (PROFIsafe,
FSEND/FRECV).
Program con‐
Switch control system OFF and ON again.
tinuation
27073
Checksum error S7 PROFIsafe configuration. Confirmation and acceptance test required!
Parameter
Explanation
The F-parameters required for PROFIsafe communication are protected by a checksum. The alarm indicates
that the actual checksum no longer matches the saved checksum, i.e. that either a piece of data was illegally
changed or is corrupt.
Response
Alarm display
Interface signals are set
NC start disable in this channel
NC stop for alarm
Mode group not ready
Channel not ready
Remedy
Check the PROFIsafe configuring on the S7 side, recalculate the checksum and correct. Re-accept the safety
functions (PROFIsafe I/O).
Program con‐
Switch control system OFF and ON again.
tinuation