14710
Channel %1 Block %2 Error in initialization sequence in function %3
Remedy
Please inform the authorized personnel/service department
For parameter %3=0-3:
If the alarm(s) occur(s) at RESET:
Check the setting of machine data MD20110 $MC_RESET_MODE_MASK, MD20120 $MC_TOOL_RE‐
SET_VALUE, MD20121 $MC_TOOL_PRESEL_RESET_VALUE, MD20122 $MC_TOOL_RESET_NAME
(only when tool management is active), MD20130 $MC_CUTTING_EDGE_RESET_VALUE, MD20132
$MC_SUMCOR_RESET_VALUE, MD20126 $MC_TOOL_CARRIER_RESET_VALUE, MD20150
$MC_GCODE_RESET_VALUES, MD20154 $MC_EXTERN_GCODE_RESET_VALUES, MD20140
$MC_TRAFO_RESET_VALUE, MD21330 $MC_COUPLE_RESET_MODE_1, MD24002
$MC_CHBFRAME_RESET_MASK.
For parameters %3= 100 -104:
Check the setting of MD20112 $MC_START_MODE_MASK and "..._RESET_..." specified under RESET
machine data. When the tool manager is active, possibly unload the tool - specified in the associated alarm
- from toolholder/spindle - or reset the "locked" state.
For parameters %3= 4 or 5:
Check the macrodefinitions in _N_DEF_DIR. Check cycle directories _N_CST_DIR and _N_CUS_DIR.
For parameter %3= 6:
In addition, Alarm 18002 or 18003 is output. This alarm contains the number of the incorrectly defined pro‐
tection zone and an identifier defining what is incorrect in the protection zone definition. The system variables
must then be appropriately corrected.
For parameter %3= 200 to 203:
Increase MD28070 $MC_MM_NUM_BLOCKS_IN_PREP.
Program con‐
Clear the alarm with the RESET key. Restart the part program.
tinuation
14751
Channel %1 Block %2 Insufficient resources for motion-synchronized actions (identifier: %3)
Parameter
%1 = channel number
%2 = block number
%3 = identifier
Explanation
To process motion synchronizing actions resources are required. They are configured using machine data
$MC_MM_IPO_BUFFER_SIZE, $MC_MM_NUM_BLOCKS_IN_PREP, $MC_MM_NUM_SAFE_SYNC_ELE‐
MENTS, $MC_MM_NUM_SYNC_ELEMENTS. If these resources are insufficient for executing the part pro‐
gram, then this alarm is issued. The parameter %3 shows which resource has run out:
Identifier ≤ 2: increase $MC_MM_IPO_BUFFER_SIZE or $MC_MM_NUM_BLOCKS_IN_PREP.
Identifier > 2: increase $MC_MM_NUM_SYNC_ELEMENTS, $MC_MM_NUM_SAFE_SYNC_ELEMENTS.
Response
Alarm display
Interface signals are set
Remedy
Correct the part program or increase the resources.
Program con‐
Clear the alarm with the RESET key. Restart the part program.
tinuation
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
11.2 NCK safety alarms for SINUMERIK 840D sl