p9858
SI transition time STOP F to STOP A (Motor Module)
Sets the transition period from STOP F to STOP A on the Motor Module/Hydraulic
Module.
See also: p9658, r9895 and F30611
For a crosswise data comparison between p9658 and p9858, a difference of one
safety monitoring clock cycle is tolerated. The parameterized time is internally
rounded-off to an integer multiple of the monitoring clock cycle.
STOP F: Defect in a monitoring channel (error in the CDC)
STOP A: STO as a result of a fault identified by Safety Integrated
Unit:
Default value:
μs
0
r9870[0...3]
SI version, safety functions integrated in the drive (Motor Module)
Displays the Safety Integrated version for the drive-integrated safety functions on
the Motor Module/Hydraulic Module.
[0]: Safety version (major release)
[1]: Safety version (minor release)
[2]: Safety version (base level or patch)
[3] = safety version (hotfix)
See also: r9770, r9890
Example:
r9870[0] = 2, r9870[1] = 60, r9870[2] = 1, r9870[3] = 0
--> safety version V02.60.01.00
Unit:
Default value:
-
-
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Minimum value:
Maximum value:
0
30000000.00
Minimum value:
Maximum value:
-
-
Data descriptions
9.2 Parameters for SINAMICS S120
Checksum:
Protection level:
Yes
3
Data type:
Effectiveness:
Floating Point32
When exiting the
SI commissioning
mode
Checksum:
Protection level:
No
3
Data type:
Effectiveness:
Unsigned16
-
459

Advertisement

Table of Contents
loading

Table of Contents