Siemens SINUMERIK 840D sl Function Manual page 341

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

13333
Meaning:
corresponds with ...
Additional reference
13334
MD number
Default value 288
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13335
MD number
Default value 0.5
Change becomes effective after: POWER ON
Data type: DOUBLE
Meaning:
corresponds with ...
Additional reference
13336
MD number
Default value 0
Change becomes effective after: POWER ON
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MN_SAFE_SDP_CONNECTION_NR[0...15]
This machine data is used to set the number of the F_SENDDP-SPL connection which is
parameterized with this data set. The F_SENDDP-SPL connection number is, at the same
time, also the index to access the system variables of the user interface of this F_SENDDP-
SPL connection.
This applies to the following system variables:
$A_FSDP_ERR_REAC
$A_FSDP_ERROR
$A_FSDP_SUBS_ON
$A_FSDP_DIAG
Example:
MD13333 $MN_SAFE_SDP_CONNECTION_NR[2] = 3 means that the control and status
information of the F_SENDDP-SPL connection, which is parameterized via data set 2, can be
found in the system variables with the field index 3.
$MN_SAFE_SDP_LADDR[0...15]
log. basis address of the input/output data area F_SENDDP
Min. input limit: 288
The start address of the input and output data area, parameterized in SIMATIC STEP 7, via
which the F_SENDDP of this SPL connection communicates.
SIMATIC block parameters: LADDR
$MN_SAFE_SDP_TIMEOUT[0...15]
Monitoring time for F_SENDDP
Min. input limit: 0.0
The monitoring time is the time within which the F_SENDDP sends a new F-telegram to
F_RECVDP or F_RECVDP must have acknowledged a new F-telegram. When the monitoring
time is exceeded, F_RECVDP outputs substitute values to the SPL.
SIMATIC block parameters: TIMEOUT
$MN_SAFE_SDP_ASSIGN[0...15]
Output assignment $A_OUTSE to F_SENDDP net data
Min. input limit: 0
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
Protection level: 7/2
Protection level: 7/2
Data descriptions
Max. input limit: 32767
Unit: -
Max. input limit: 60
Unit: s
Max. input limit: 192192
Unit: -