r9747[0...63]
SI message code
Displays the number of the safety messages that have occurred.
See also r9744, r9748, r9749, r9754, p9752, r9753, r9754, r9755, r9756, r9759
"Safety message" (Cxxxxx) type messages are entered in the safety message
buffer.
Message buffer structure (principle):
r9747[0], r9748[0], r9749[0], r9753[0], r9754[0], r9755[0], r9756[0] → actual mes‐
sage case, safety message 1
...
r9747[7], r9748[7], r9749[7], r9753[7], r9754[7], r9755[7], r9756[7] → actual mes‐
sage case, safety message 8
r9747[8], r9748[8], r9749[8], r9753[8], r9754[8], r9755[8], r9756[8] → 1. Acknowl‐
edged message case, safety message 1
...
r9747[15], r9748[15], r9749[15], r9753[15], r9754[15], r9755[15], r9756[15]→ 1.
Acknowledged message case, safety message 8
...
r9747[56], r9748[56], r9749[56], r9753[56], r9754[56], r9755[56], r9756[56] → 7.
Acknowledged message case, safety message 1
...
r9747[63], r9748[63], r9749[63], r9753[63], r9754[63], r9755[63], r9756[63] → 7.
Acknowledged message case, safety message 8
Unit:
Default value:
-
-
r9748[0...63]
SI message time received in milliseconds
Displays the relative system runtime in milliseconds when the safety message
occurred.
See also r9744, r9747, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Unit:
Default value:
ms
-
r9749[0...63]
SI message value
Displays the additional information about the safety message that occurred (as
integer number).
See also r9744, r9747, r9748, p9752, r9753, r9754, r9755, r9756, p9759
Unit:
Default value:
-
-
r9750[0...63]
SI diagnostic attributes
Displays the diagnostic attribute of the safety message that has occurred
Bit 00 hardware replacement recommended
Unit:
Default value:
-
-
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Minimum value:
Maximum value:
-
-
Minimum value:
Maximum value:
-
-
Minimum value:
Maximum value:
-
-
Minimum value:
Maximum value:
-
-
Data descriptions
9.2 Parameters for SINAMICS S120
Checksum:
Protection level:
-
3
Data type:
Effectiveness:
Unsigned16
-
Checksum:
Protection level:
-
3
Data type:
Effectiveness:
Unsigned32
-
Checksum:
Protection level:
-
3
Data type:
Effectiveness:
Integer32
-
Checksum:
Protection level:
-
3
Data type:
Effectiveness:
Integer32
-
447