Siemens SINUMERIK 840D sl Function Manual page 747

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

NCK
alarm
number
27021
27022
27023
27024
All of the NCK alarms, which can be prevented from being initiated twice due to a PLC request,
are listed in the following table.
NCK alarm
number
27090
27091
27092
27095
27250
27251
27252
27253
27254
27255
27256
Activation
The alarm is suppressed using MD10094 $MN_SAFE_ALARM_SUPPRESS_LEVEL. When
standard data is loaded, the function is already active. This means that a reduced number/
scope of alarms is displayed. Alarms 27000 and C01797 can be replaced via MD10094 with
Alarm 27100.
MD $MN_SAFE_ALARM_SUPPRESS_LEVEL can also be used to set that Alarm 27040 is
replaced by the group alarm 27140 "Waiting for motor module of at least one axis".
SPL commissioning mode
The following alarm reductions are made in the commissioning phase:
The axis-specific acceptance test alarm 27032 "Axis %1 checksum error safe monitoring
functions. Confirmation and acceptance test required!", 27035 "Axis %1 new hardware
component, confirmation and functional test required" and 27060 "Axis %1 Drive assignment
checksum error, confirmation and acceptance test required!" are replaced by the axis-specific
group alarm 27132 "Axis %1 checksum group error safe monitoring functions. Confirmation
and acceptance test required", replaced.
An additional alarm reduction can be set using MD $MN_SAFE_ALARM_SUPPRESS_LEVEL
(100's position set). As a result, the axis-specific acceptance test alarms are replaced by the
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
SINAMICS
Alarm suppression using the following values in $MN_SAFE_ALARM_SUP‐
S120 alarm
PRESS_LEVEL, several values are alternatively possible
number
C01709
1, 2, 3, 12, 13
C01708
1, 2, 3, 12, 13
C01701
1, 2, 3, 12, 13
C01700
1, 2, 3, 12, 13
Alarm suppression using the following values in $MN_SAFE_ALARM_SUPPRESS_LEV‐
EL, several values are alternatively possible.
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
2, 3, 12, 13
11.5 Reducing the number of alarms
Diagnostics
747