Siemens SINUMERIK 840D sl Function Manual page 323

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

10094
Special cases, errors,...
10095
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
Special cases, errors,...
corresponds with:
10096
MD number
Default value: 1
Change becomes effective after: NewConf
Data type: DWORD
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MN_SAFE_ALARM_SUPPRESS_LEVEL
This machine data must be set to 0 to generate an acceptance report. This allows the system
to document all of the alarms that have been initiated.
$MN_SAFE_MODE_MASK
Safety Integrated operating modes
Min. input limit: 0
Bit 1=0: The "Modular PROFIsafe I/O interface" function is not active.
Bit 1=1: The "Modular PROFIsafe I/O interface" function is active.
Bit 2=0: The reduced language scope for SAFE.SPF is only activated for an automatic start
when booting (MD20108 $MC_PROG_EVENT_MASK bit 5)
Bit 2=1: The reduced language scope for SAFE.SPF is also activated if SAFE.SPF is called
using the CALL command
Bit 3=0: all PROFIsafe drivers in one IPO clock cycle
Bit 3=1: PROFIsafe driver distributed over several IPO clock cycles
Bit 4=0: in safety operating mode "SINUMERIK Safety Integrated (SPL)", it is not possible to
couple NC axes to the drive monitoring functions via SIC/SCC
Bit 4=1: in safety operating mode "SINUMERIK Safety Integrated (SPL)", it is permissible to
couple NC axes to the drive monitoring functions via SIC/SCC
Bit 1:
MD13302 $MN_PROFISAFE_IN_ENABLE_MASK
MD13303 $MN_PROFISAFE_OUT_ENABLE_MASK
Bit 2:
MD20108 $MC_PROG_EVENT_MASK, bit 5
$MN_SAFE_DIAGNOSIS_MASK
Safety Integrated diagnostic functions
Min. input limit: 0
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
Protection level: 7/2
Data descriptions
Max. input limit: 0x001E
Unit: -
Max. input limit: 0x000F
Unit: -