F30659
SI P2: Write task for parameter rejected
Explanation
The write task for one or several Safety Integrated parameters on monitoring channel 2 was rejected.
Note:
This fault does not result in a safety stop response.
Fault value (r0949, interpret decimal):
10: An attempt was made to enable the STO function although this cannot be supported.
11: An attempt was made to enable the SBC function although this cannot be supported.
13: An attempt was made to enable the SS1 function although this cannot be supported.
14: An attempt was made to enable the safe motion monitoring with the higher-level control although this
cannot be supported.
15: An attempt was made to enable the motion monitoring functions integrated in the drive although these
cannot be supported.
16: An attempt was made to enable PROFIsafe communication, although this cannot be supported or the
version of the PROFIsafe driver is different in both monitoring channels.
19: An attempt was made to enable the pulse suppression delay for ESR, although this cannot be supported.
See also: r9771 (SI common functions (Control Unit)), r9871 (SI common functions (Motor Module))
Remedy
● For fault value = 10, 11, 13, 14, 15, 16, 19:
Check whether there are faults in the safety function alignment between the two monitoring channels
(F01655, F30655), and if required carry out diagnostics for the faults involved. Use a Motor Module that
supports the required function.
Upgrade the Motor Module software.
Upgrade the Control Unit software.
F30672
SI P2: Control Unit software incompatible
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Explanation
The existing Control Unit software does not support the safe drive-integrated motion monitoring function.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy
Check whether there are faults in the safety function alignment between the two monitoring channels
(F01655, F30655), and if required carry out diagnostics for the faults involved.
● Use a Control Unit that supports the safety-related motion monitoring functions.
● Upgrade the Control Unit software.
F30680
SI Motion P2: Checksum error safe monitoring functions
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
11.3 Safety messages for SINAMICS S120
Diagnostics