Enter/Exit Programming Mode
Illumination During Disable Mode
This feature allows illumination to be turned off when the scanner is in "disable"
mode. It determines if the imager illumination is controlled by host interface
enable/disable commands.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan your selection from the barcodes below.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
063A01(CR)
Illumination During Disable Mode = Enable
42
= Illumination is not controlled by host enable/disable commands,
Disable
illumination stays on when disabled.
= Illumination is controlled by host enable/disable commands, illu-
Enable
mination is on when enabled and off when disabled.
gramming Mode barcode.
Illumination During Disable Mode
063A00(CR)
Illumination During Disable Mode = Disable
DEFAULT