RAP 2.1 Blank Control Panel
Display
WARNING
Improper connection of the grounding
conductor can result in the risk of electrical
shock. The following must be observed:
Never use a ground adapter plug to
connect the terminal to a power source
which
does
not
have
connection.
Never attempt any maintenance function
which is not specifically called out in the
service procedures.
Never remove any covers which are
fastened
with
screws,
instructed in the service procedures.
CAUTION
If any of the voltage measurements are not as
specified in the following steps, the cause
must be corrected. Caution the customer not
to connect the terminal to the wall outlet.
Advise the customer that a licensed electrician
must correct the wiring.
Do not attempt to
correct the wiring yourself.
If you later find
the condition has not been corrected, inform
your manager in writing of the improper
wiring.
1. Perform the following line voltage check.
a. Disconnect the power cord from the
wall outlet.
Telecopier 7032 / 7033 Service Manual
b. USO only (Figure 1).
following:
Measure the AC voltage between
AC Hot and Neutral.
104 to 127 VAC.
Measure the AC voltage between
the AC Neutral and GND. Meter
= less than 3 VAC.
RX, UK Only (Figure 2). Perform the
a
ground
following:
Measure the AC voltage between
live and neutral and between live
and earth.
VAC.
Measure the AC voltage between
unless
so
Neutral and Earth. Meter = less
than 3 VAC.
RX, Europe Only (Figure 3). Perform
the following:
Measure the AC voltage between
supply pins. Meter = 196 to 244
VAC.
Measure the AC voltage between
one supply pin and earth.
Meter = 196 to 244 VAC.
Measure the AC voltage between
second supply pin and earth.
Meter = 3 VAC or less.
The voltages are correct.
Y
N
|
Inform
insufficient voltage (or improper
wiring).
www.printcopy.info
Perform the
Meter =
Meter = 216 to 264
the
customer
of
8/91
2-15
USO
AC Neutral
(ACN)
GND
Figure 1. USO Wall Outlet
RX Only
Earth
Live
Neutral
Figure 2. RX UK Wall Outlet
RX Only
Supply pins
Figure 3. RX Europe Wall Outlet
AC Hot
(ACH)
7033-100
7033-101
Earth
7033-102