Rap 2.17 Image Quality On Copy; Rap 2.18 Dial Tone Is Not Heard - Xerox Telecopier 7033 Service Manual

Table of Contents

Advertisement

11. Problem
occurs
ONLY
terminal initiates the telephone call.
Y
N
|
Contact
additional
support.
12. Suspect remote telephone system or long
distance vendor. Go to Final Actions.
13. Protocol Monitor printout is performed
after the receive operation.
Y
N
|
Rerun the test until an error code
is
displayed,
according to code.
If problem cannot be duplicated,
contact
additional
support.
14. Contact additional technical support for
interpretation of printout.
AP 2.15, 2.16

RAP 2.17 Image Quality on Copy

when
remote
1. Perform the following:
technical
a. Open the scanner, and clean the
video assembly.
b. Perform a copy operation using test
pattern 82P151.
c. Compare the quality of the copy to
the original, and to the test pattern
sample in Section 3.
Copy quality is acceptable.
Y
then
repair
|
2. Perform the System Check.
technical
3. Perform the following:
a. Perform Test 01, Test Pattern Type A.
b. Compare the quality of the test
pattern to the sample in section 3.
Print quality is acceptable.
Y
|
4. Perform the following:
a. Perform Test 03, Test Pattern Type C.
b. Compare the quality of the test
pattern to the sample in section 3.
Print quality is acceptable.
Y
|
5. Replace the video assembly. If problem
still exists, replace the main PWB.
N
Go to step 3.
N
Replace in order:
• thermal head
• RAM/ROM PWB
• main PWB
N
Replace in order:
• RAM/ROM PWB
• main PWB
8/91
2-27
www.printcopy.info

RAP 2.18 Dial Tone is Not Heard

1. Display indicates:
CALL UNSUCCESSFUL - WAITING FOR
REDIAL
TO CANCEL - SELECT PENDING JOB
Y
N
|
Verify that the telephone line
cord is connected to terminal and
wall outlet. Replace in order:
• G3 PWB
• coupler PWB (RX only)
2. Perform the following:
a. Disconnect the handset cord from the
terminal.
b. Disconnect the telephone line cord
from the wall jack.
c. Plug the handset cord into the wall
jack.
Dial tone is heard.
Y
N
|
Inform
customer
line problem.
3. Reseat connectors, then replace in order:
telephone line cord
G3 PWB
coupler PWB (RX only)
telephone line filter PWB (RX only)
If problem still exists, contact additional
technical support.