6.3.4 Electrical Specifications

Single phase (2 wires plus ground)
Voltage:
USO
104 to 127 VAC (nominal 115 VAC)
@ 50 Hz ± 1 Hz or 60 Hz ± 1 Hz
RX
200 to 240 VAC (nominal 220 VAC)
@ 50 Hz ± 1 Hz or 60 Hz ± 1 Hz
Power Consumption (maximum)
Operating 230 W
Standby
65 W
A standard two pole, three wire grounded
receptacle is required.
Meter Readings (USO)
Between AC Hot and Neutral 104 to 127 VAC
Between Gnd and AC Hot
104 to 127 VAC
Between Gnd and Neutral (longer slot) less
than 3 VAC
Meter Readings (RX)
Between AC Live and Neutral 200 to 240 VAC.
Between AC Live and Neutral 130 VAC.
Between Gnd and Return 130 VAC.
6.4, 6.4.1, 6.4.2, 6.5, 6.5.1

6.3.5 Environmental Specifications

o
o
Temperature
60
to 90
F (15
Humidity
15% to 85%
w/o condensation
Elevation
Maximum
(3,000 metres) above sea
level
Heat Dissipation
Operating 785 BTU/Hr
Standby

6.3.6 Recording Paper

The following paper is recommended for use
in the 7033 terminal.
USO
Xerox 4024 DP copy paper
Xerox 10 Series Smooth copy paper
RX
Xerox 80 gm copy paper

6.3.7 Donor Film

USO
Length
656'
(200 M)
Width
8.6"
(220 mm)
USO Starter Roll
Length
197'
(60 M)
Width
8.6"
(220 mm)
RX
Length
656'
(200 M)
Width
10.2"
(260 mm)
RX Starter Roll
Length
197'
(60 M)
Width
10.2"
(260 mm)
6/92
www.printcopy.info
6-19

6.3.8 Original Stacking Requirements

o
o
to 32
C)
Originals are loaded into the ADF face down
and lead edge to the left. They are aligned by
adjusting the document guides to the width of
9,900
feet
the originals.
Originals loaded in the ADF may be mixed in
weight and length, but should not be mixed in
width.
221 BTU/Hr
Weight
13 to 36 pound (45 to 127.9 grams/
square meter)
Width
4.1 to 11.7 inches (105 to 297 mm)
Length
4.5 to 18.1 inches (144 to 420 mm)
NOTE: Originals longer than 18.1 inches
(420 mm) can be used by manually assisting
the ADF.
(900 mm) also require the selection of the long
original feature.
The input tray (ADF) capacity for 13 to 36
pound (45 to 127.9 grams/square meter) paper
is 50 documents. Mixed weight stacks of more
than 30 documents shall include a maximum
of four 32 or 36 pound documents.
Telecopier 7032 / 7033 Service Manual
Originals longer than 36 inches