3. Remove rear cover (PL 5.1A)
a. Disconnect power cord, telephone line cord, and handset cord from
rear of terminal, and remove handset from cradle.
b. Remove PWB access cover.
If installed, disconnect RS-232 and/or encryption interface
cables(s).
Remove one screw securing panel.
c. Remove left rear cover screw (Figure 2).
d. Lower the right side cover, and remove right rear cover screw.
e. Remove one screw (on rear of terminal) securing rear cover.
f. While lifting rear cover up, pull bottom sides away from terminal.
Telecopier 7032 / 7033 Service Manual
4. Remove EMI shield. (PL 5.1.0)
a. Loosen five screws (Figure 3).
b. Lift off EMI shield.
During replacement, ensure all wire harnesses feed through the cutouts in the
EMI shield. Do not pinch wires between the shidl and electrical box.