X46 Brake Control And Monitoring - Siemens SINAMICS S120 Manual

Cabinet modules
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Note
Safety Integrated Function Manual
Detailed and comprehensive instructions and information for the Safety Integrated functions
can be found in the associated Function Manual. This manual is available as additional
documentation on the customer DVD supplied with the device.
Note
EP terminals only for Safety Integrated Basic Functions
The function of the EP terminals is only available when Safety Integrated Basic Functions
are enabled.
8.22.4.3

X46 Brake control and monitoring

Table 8- 30
Max. connectable cross-section: 2.5 mm
NOTICE
Cable length
The length of the connecting cable at terminal strip -X46 must not exceed 10 m, and the
cable must not be brought out to outside the control cabinet or control cabinet group.
Cabinet Modules
Manual, 03/2013, A5E03263538A
Terminal block X46 on the customer terminal block X55
Terminal
Function
1
BR output +
2
BR output -
3
FB input +
4
FB input -
8.22 K95, Control Unit CU320-2 PN
Technical data
This interface is intended for the connection of the
Safe Brake Adapter.
2
Options
449

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents