X520 encoder connection 1 for HTL/TTL/SSI encoder with open-circuit monitoring
Table 8- 12
Encoder connection X520
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type: 15-pin Sub-D socket
NOTICE
Setting the encoder power supply
The encoder power supply can be parameterized to 5 V or 24 V. The encoder may be
destroyed if you enter the wrong parameter.
KTY temperature sensor connected with the correct polarity
The KTY temperature sensor must be connected with the correct polarity.
If the polarity is reversed, the sensor will not be able to detect if the motor overheats.
Risk of electric shock!
Only temperature sensors that meet the safety isolation specifications stipulated in
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp".
Failure to observe these instructions can result in electric shock!
Cabinet Modules
Manual, 03/2013, A5E03263538A
Signal name
+Temp
Clock
Clock*
P encoder 5 V / 24 V
P encoder 5 V / 24 V
P sense
M encoder (M)
-Temp
M sense
R
R*
B*
B
A*/data*
A/data
CAUTION
DANGER
8.11 K50, Sensor Module Cabinet-Mounted SMC30
Technical data
Motor temperature sensing KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130/PTC/
bimetallic switch with NC contact
SSI clock
Inverted SSI clock
Encoder power supply
Encoder power supply
Sense input for encoder power supply
Ground for encoder power supply
Motor temperature sensing KTY84-1C130 (KTY-)
Temperature sensor KTY84-1C130/PTC/
bimetallic switch with NC contact
Ground for sense input
Reference signal R
Inverted reference signal R
Inverted incremental signal B
Incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data
Options
401

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents