Siemens SINAMICS S120 Manual page 404

Cabinet modules
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Options
8.11 K50, Sensor Module Cabinet-Mounted SMC30
X521/X531 encoder connection 2 for HTL/TTL/SSI encoder with open-circuit monitoring
Table 8- 13
Encoder connection X521
Terminal
1
2
3
4
5
6
7
8
Max. connectable cross-section: 1.5 mm²
Note
Operation of unipolar HTL encoders
When unipolar HTL encoders are used, terminal block A*, B*, and R* must be jumpered with
M encoder (-X531).
Table 8- 14
Encoder connection X531
Terminal
1
2
3
4
5
6
7
8
Max. connectable cross-section: 1.5 mm²
Note
Cable shield for the encoder connection via terminals
Note that when the encoder is connected via terminals, the cable shield must be applied to
the module.
KTY temperature sensor connected with the correct polarity
The KTY temperature sensor must be connected with the correct polarity.
If the polarity is reversed, the sensor will not be able to detect if the motor overheats.
402
Signal name
A
A*
B
B*
R
R*
CTRL
M
Signal name
P encoder 5 V / 24 V
M encoder
-Temp
+Temp
Clock
Clock*
Data
Data*
CAUTION
Technical data
Incremental signal A
Inverted incremental signal A
Incremental signal B
Inverted incremental signal B
Reference signal R
Inverted reference signal R
Control signal
Ground
Technical data
Encoder power supply
Ground for encoder power supply
Motor temperature sensing KTY84-1C130 (KTY-)
Temperature sensor KTY84-1C130/PTC/
bimetallic switch with NC contact
SSI clock
Inverted SSI clock
SSI data
Inverted SSI data
Cabinet Modules
Manual, 03/2013, A5E03263538A