Siemens SINAMICS S120 Manual page 354

Cabinet modules
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics
7.3 LEDs on the CU320-2 PN Control Unit
Behavior of the LEDs after booting
Table 7- 6
Control Unit CU320-2 PN – Description of the LEDs after booting
LED
Color
RDY (READY)
-
Green
Red
Red/
green
Orange
Green/
orange
or
red/
orange
DP
PROFIdrive
cyclic
operation
Green
352
State
OFF
The electronics power supply is missing or lies
outside the permissible tolerance range.
Steady light The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
Flashing
Commissioning / reset
light
0.5 Hz
Flashing
Writing to CompactFlash card
light
2 Hz
Flashing
General errors
light
2 Hz
Flashing
Control unit is ready for operation.
light
However, there are no software licenses.
0.5 Hz
Flashing
Updating the firmware of the connected DRIVE-
light
CLiQ components
0.5 Hz
Flashing
DRIVE-CLiQ component firmware update has
light
been completed. Wait for POWER ON of the
2 Hz
respective component.
Flashing
Component detection via LED is activated
light
(p0124[0]).
1 Hz
Note:
Both options depend on the LED status when
component detection is activated via
p0124[0] = 1.
Off
Cyclic communication has not (yet) taken place.
Note:
PROFIdrive is ready to communicate when the
Control Unit is ready to operate (see LED RDY).
Steady light Cyclic communication is taking place.
Flashing
Full cyclic communication has not yet taken
light
place.
0.5 Hz
Possible causes:
The controller is not transferring any
setpoints.
During isochronous operation, no global
control (GC) or a faulty global control (GC) is
transferred by the controller.
"Shared Device" is selected (p8929 = 2) and
only one controller is connected.
Description, cause
Remedy
Check power supply
Check parameterization /
configuration data
Upgrade licenses
Carry out POWER ON for
the components in question
Cabinet Modules
Manual, 03/2013, A5E03263538A

Hide quick links:

Advertisement

Table of Contents
loading